Site Report: Fujisawa Technology Center
- Major offices/Factories:
- Fujisawa Technology Center
- Shonan Factory
- Isehara Factory
- Hadano Factory
- Azbil Kyoto Co., Ltd.
- Azbil Taishin Co., Ltd
- Azbil Control Instruments (Dalian) Co., Ltd.
- Azbil Hong Kong Limited ShenZhen Plant
Factory data
![]() |
| |
Location :
1-12-2 Kawana, Fujisawa-shi, Kanagawa-ken, Japan 251-8522
Role :
Research and development, and engineering
Started operation :
1961
Site area :
29,400m²
Floor space :
51,451m²
No. of employees :
Approximately 1,900
ISO 14001 certification :
August 12, 1996
Environment-related accidents/complaints :
One instance in February 2012*1
*1: This was reported to the appropriate authorities and carrected.
Environmental performance data


Water quality
| Main categories | BOD | SS | n-hexane |
| Permissible level | 600mg/l | 600mg/l | 30mg/l |
| Max. measured level | 280mg/l | 300mg/l | 25mg/l |
Industrial wastewater (FY 2011)
| Main categories | ph | BOD | COD | SS | n-hexane |
| Permissible level | 5.8-8.6 | 15mg/l | 25mg/l | 40mg/l | 5mg/l |
| Max. measured level | 7.8 | 4mg/l | 2mg/l | Less than 1mg/l | Less than 1mg/l |
pH: Hydrogen ion concentration
BOD: Biochemical oxygen demand
COD: Chemical oxygen demand
SS: Suspended solids
n-hexane (animal/vegetable oils)
Atmosphere
| Main categories | dust concentration | Amount of dust | nitrogen oxide | sulfur oxide |
| Permissible level | 0.1g/Nm³ | 89.3g/h | 60ppm(0%O2) | * The measurement is unnecessary because of the city gas |
| Max. measured level | 0.0026g/Nm³ | Less than 1mg/l | 32ppm(0%O2) | --- |
The nitrogen oxide is a corresponding value to 0% in the density of oxygen.
Waste
Tour of the energy-saving model factory
Awards
| February 2005 | Receives the Director-General Prize from the Agency for Natural Energy and Resources, in the Awarding of Excellent Energy Conservation Factory & Building, Electrical divisions |
| February 2005 | Receives the Chairman Prize of the Energy Conservation Center Japan, in the Awarding of a Successful Case of Energy Conservation in a Factory or Building |
| June 2006 | Receive Award for Excellent Environmental Management, Environmental Management section, at the 4th Japan Environmental Management Awards |
| August 2007 | Yamatake Corporation(presently Azbil Corporation) 's new technology building receives both the New Office Promotion Award and Environment Award at the 20th Nikkei New Office Awards |
| March 2008 | Yamatake Corporation(presently Azbil Corporation) receives Awards Committee Special Prize at the 6th Japan Environmental Management Awards. |
| October 2009 | Yamatake Corporation(presently Azbil Corporation) receives Encouragement prize at the FY2010 Improvement case with thermal storage system driving management. |
| December 2009 | Yamatake Corporation(presently Azbil Corporation) receives The Kanagawa earth environmental prize from Kanagawa Conference for Promotion of Global Environment Conservation. |
| March 2012 | The Fujisawa Technology Center receives The Kanagawa earth environmental prize and electricity conservationgrand-prix. |