Flame Safeguard (FSG) Controls
Dynamic Self-Checking Burner Controller with Communications Function
AUR450C
The AUR450C is a burner controller with a dynamic self-checking function, and is used in combination with the AUD300C or AUD500C Advanced Ultraviolet Detector. Catalog (aur450c_e) User's Manual (CP-SP-1264E) User's Manual for Communications (CP-SP-1176E) User's Manual for SLP-A45 Smart Loader Package (CP-SP-1187E) |
Advanced Ultraviolet Relay with Communications
AUR350C
The AUR350C Advanced UV Relay with Communications is a safe combustion controller with a dynamic self-checking function, and is used in combination with the AUD300C Advanced UV Sensor. Catalog (aur350c_e) Specification Sheet (CP-SS-1817E) User's Manual (CP-SP-1175E) ser's Manual for SLP-A35 Smart Loader Package (CP-SP-1186E) |
Advanced Ultraviolet Relay
AUR300C
The AUR300C is a relay with a dynamic self-checking function, and is used in combination with the AUD300C or AUD500C Advanced Ultraviolet Detector. The AUR300C controls its built-in flame relay while constantly driving the shutter of the UV detector to check for any malfunction in itself or in the UV detector. If the detector or amplifier circuit fails for any reason, the relay shuts itself off automatically and secures the safety of the system. Catalog (aur300c_e) Specification Sheet (CP-SS-1807E) User's Manual (CP-SP-1142E) |
Protectorelay Flame Safeguard Controls
R4715B/C
The R4715B and R4715C are flame safeguard controls used to provide automatic operation and safety of combustion in small and medium sized gas-fired burners that have a maximum burning capacity of 175kW/h (150,000Kcal/h) or less. Catalog (r4715b_c_e) User's Manual (ai-1186e) |
Protectorelay Flame Safeguard Controls
R4424C/D/E
The R4424C/D/E are flame safeguard controls used to provide automatic operation and safety of combustion in batch-type compact-sized oil-fired burners. |
Protectorelay Flame Safeguard Control
R4440H
The R4440H is a flame safeguard control used to provide automatic operation in correct sequence and with safe combustion for batch-type small sized oil-fired burners. Catalog (r4440h_e) |
Protectorelay Flame Safeguard Controls
R4750B/C
The R4750B and R4750C are flame safeguard controls used to provide
automatic operation and safety of combustion in medium sized gas-fired
burners that have a maximum burning capacity of 580kW/h (500,000Kcal/h)
or less. Catalog (r4750b_c_e) User's Manual for R4750B (ai-1187e) User's Manual for R4750C (CP-UM-1132E) |
Protectorelay Flame Safeguard Controls
R4780B/C/D
The R4780B/C/D are flame safeguard controls used to provide automatic
operation and safety of combustion in oil-fired, gas-fired, or oil-gas fired
burners that have a burning capacity of 580kW/h (500,000Kcal/h) or
greater. Catalog (r4780b_c_d_e) User's Manual (CP-UM-1133E) |
Multiburner Control Flame Relay
FRS100
The FRS100 is a flame safeguard control with a self-checking circuit to
ensure safe start-up operation. If abnormal conditions exist, ignition start
is prevented or system safety is secured by the shutdown of combustion if
the main flame fails during operation. Catalog (frs100_e) Specification Sheet (CP-SS-1720E) User's Manual (CP-SP-1074E) |
Advanced Ultraviolet Detector
AUD300C
The AUD300C is a flame detector designed to sense the ultraviolet radiation from an oil or gas burner flame. This unit is used in combination with the dedicated AUR400C/450C or AUR300C/350C. Any malfunction that has occurred in the UV detector or UV relay can be detected by the continuous and highly accurate dynamic self-check function of the built-in shutter driven by the relay, ensuring extremely reliable combustion safety control. Catalog (aud300c_e) Specification Sheet (CP-SS-1823E) User's Manual (CP-SP-1170E) User's Manual for AUD60A2100/2110 Maintenance Kit (CP-UM-5441JE) User's Manual for AUD50A2100 Shutter Unit (CP-UM-5346JE) User's Manual for AUD10C2100 Tube Unit (CP-UM-5347JE) |
Explosion-Proof Advanced Ultraviolet Detector
AUD500C
The AUD500C is an explosion-proof flame detector designed to sense the ultraviolet radiation from an oil or gas burner flame. This unit is used in combination with the dedicated AUR400C/450C or AUR300C/350C. Any malfunction that has occurred in the UV detector or UV relay can be detected by the continuous self-checking function of the built-in shutter driven by the relay, ensuring highly reliable combustion safety control. Catalog (aud500c_e) User's Manual (CP-SP-1181E) User's Manual for AUD60A2100/2110 Maintenance Kit (CP-UM-5441JE) User's Manual for AUD50A2100 Shutter Unit (CP-UM-5346JE) User's Manual for AUD10C2100 Tube Unit (CP-UM-5347JE) |
Flame Rods
C7007A, C7008A
The C7007A and C7008A are used with a rectification-type Protectorelay as a flame detector for gas-fired pilot burners. Catalog (c7007a,c7008a_e) |
Minipeeper Ultraviolet Flame Detector
C7035A
The C7035A is a compact flame detector for use with flame safeguard
controls (Protectorelays) with ultraviolet amplifiers. Catalog (c7035a_e) User's Manual (CP-UM-1142E) User's Manual for 129464NJ UV Tube (CP-SP-1040E) |
Adjustable Sensitivity Ultraviolet Flame Detector
C7076A
The C7076A is a solid-state, dynamic, self-checking flame detector for use
with flame safeguard primary safety controls requiring adjustable
sensitivity ultraviolet flame detection. Catalog (c7076a_e) |
Explosion-Proof Adjustable Sensitivity
Ultraviolet Flame Detector
C7076D
The C7076D is an explosion-proof solid-state dynamic self-checking flame detector for use with appropriate flame safeguard primary safety controls requiring adjustable sensitivity ultraviolet flame detection. Catalog (c7076d_e) User's Manual (ai-1143e) |
Ignition Transformer
ATN110A-1
The ATN110A-1 is an ignition transformer for commercial and industrial burners. With a simple operation of the changeover tap, it can be used with either 100V or 200V primary voltage. Catalog (atn110a-1_e) |
Solid-State Spark Generator
S7200A
The S7200A solid-state spark generator (igniter) is a high performance ignition transformer used to ignite gun-type oil burners and power gas burners in domestic, commercial and industrial applications. The S7200A has high ignition energy, enabling it to ignite burners which conventionally could be lit only with coil-type ignition transformers. Catalog (s7200a_e) |
Solid-State Spark Generator
S720A
The S720A solid-state spark generator (igniter) is a high-performance ignition transformer used to ignite gun-type oil burners and power gas burners in domestic, commercial and industrial applications. Catalog (s7200a_e) User's Manual (ai-1190e) |