Actuators
Solid State Relays
PGM10N/F
The PGM10N and PGM10F are solid state relays with zero-cross functions
for single phase power. Catalog (pgm10n_f_e) Specification Sheet (CP-SS-1822E) |
Power Gate Unit
PGU410
The PGU410 Power Gate Unit (thyristor-type power regulator) is a phase-controlled power regulator controlled by a 4 to 20mA control signal or a manual setting device (QN740A101). Catalog (pgu410_e) User's Manual (CP-SP-1166E) |
Control Motor
ECM3000
The ECM3000 is a control motor designed to control various equipment in industrial applications. Two kinds of models are available: one has a 90° angular stroke motor for burner control and the other has a 160° angular stroke motor for valve control of hot and cold water and steam. Catalog (ecm3000_e) Specification Sheet (CP-SS-1816E) User's Manual (CP-UM-5306E) |
Motor Driver, DC/Position Proportional Converter
RN748A
The RN748A is a signal converter that receives a 4–20mA input signal from a controller and outputs a relay contact signal to drive a control motor with a built-in 135Ω feedback potentiometer for position proportioning operation. By setting the center of rotation angle and the proportional band, a split operation can be performed. Catalog (rn748a_e) User's Manual (CP-UM-5376JE) |
High-Torque Modutrol Motor
HM
The HM serves as an electric actuator to execute either 2-position or
proportional control action, with relay contact signal input. Catalog (hm_e) |
Quick-Opening Gas Solenoid Valve
VEN4000B
The VEN4000B is used for ON/OFF or safety shutoff control of a gas
burner, for city gas, natural gas or LP gas. It is available with flow rate and
quick-opening speed adjustment. Catalog (ven4000c_e) User's Manual (CP-UM-1660E) |
Slow-Opening Gas Solenoid Valve
VEN4000C
The VEN4000C is used for ON/OFF or safety shutoff control of a gas
burner, for city gas, natural gas or LP gas. It is available with flow rate,
step pressure and slow-opening speed adjustments. Catalog (ven4000c_e) User's Manual (CP-UM-1660E) |
Actival-FSG Combustion Control Motor and Valve
CCM21, CCV20
The CCM21/CCV20 is an integral actuator / electrically driven butterfly
valve incorporated with a combustion control motor and valve. The motor
uses relay contact input for position proportioning or on-off positioning. Catalog (ccm21,ccv20_e) |
CV3000 Alphaplus
Top-Guided Single-Seated Control Valves
AGVB, AGVM
The CV3000 Alphaplus range of top-guided, single-seat control valves feature a compact valve body with superior flow control and minimal pressure loss. Alphaplus valves have wide rangeability, accurate flow control and high Cv values, particularly suitable for process control applications where high reliability and tight flow shutoff are essential. Catalog (agvb,agvm_e) |