MCF Air Flowmeter
A dedicated air/nitrogen mass flowmeter, indispensable for cutting compressor energy use
- Practical measurement range of 50:1 and extended range function providing up to 2 times the standard range are useful for detecting air leakage.
- Reverse flow detection function
- Model lineup meets a variety of application requirements.
- Easy maintenance without removal from the piping
- Use a single MCF for flow in various directions
- Thermal mass flow measurement
- RS-485 MODBUS communications option for centralized air leak/consumption management
| Model No. | MCF008 | MCF015 | MCF025 | MCF040 | MCF050 |
|---|---|---|---|---|---|
| Gas types | Air/nitrogen. (Note that gas must be dry, without corrosive components such as chlorine, sulfur and acid. It must also be clean, without dust or oil mist.) |
||||
| Flow rate range [L/min (normal)]*1 | 0 to 200 |
0 to 500 |
0 to 3000 |
0 to 6000 |
0 to 12000 |
| Reverse flow range [L/min (normal)]*2 | -60 |
-150 |
-900 |
-1800 |
-3600 |
| Extended range [L/min (normal)]*3 | 400 |
1000 |
6000 |
12000 |
24000 |
| Accuracy guaranteed flow rate range [L/min (normal)]*4 | 4 to 200 |
10 to 500 |
60 to 3000 |
120 to 6000 |
240 to 12000 |
| Measurement accuracy | ±3 % FS |
||||
| Smallest detectable flow rate [L/min (normal)] | 2 |
5 |
30 |
60 |
120 |
| Display resolution [L/min (normal)] | 1 |
1 |
5 |
10 |
10 |
| Temperature | -10 to +60 ?C (without condensation) |
||||
| Storage temperature | -20 to +70 ?C (without condensation) |
||||
| Humidity | 0 to 90 % RH (without condensation) |
||||
| Pipe size | 8A(¼B)Rc |
15A(½B)Rc |
25A(1B)Rc |
40A(1½B)Rc |
50A(2B)Rc |
| Body material | Aluminum alloy, with alumite treatment on the surface |
||||
| Case material | Denatured PPO |
||||
| Operating pressure range | -0.07 to +1.0 MPa |
||||
| Pressure resistance | 1.5 MPa |
||||
| Mounting orientation | ・Horizontal (flow: left → right, right → left) ・Vertical (flow: up → down, down → up) |
||||
| Rated voltage | 24 Vdc, 120 mA max. |
||||
| Sampling cycle / response time | 50 ms to 1.5 s max. (time for 95 % of response to 0 → 100 % FS step input) |
||||
| Output signal (instantaneous flow rate) | 4?20 mA, allowable load resistance 300 ? max. |
||||
| Event output | One open collector output (rating 30 Vdc, 50 mA), with output type selectable from event function. |
||||
| Event function | Selectable from pulse output for integration*5, instantaneous flow rate high/low limit alarm, integration count up/down, or alarm output. |
||||
| Electrical connection | PA5 Series VA connector (4 pins) |
||||
| Display | 7-segment, 5-digit display changeable between instantaneous flow rate, integrated (cumulative) flow, and cost. |
||||
| Ingress protection | IP65. (Rating is based on JIS C 0920 and IEC529. For purposes of installation indoors, device is waterproof and dustproof.) |
||||
| Standards compliance | CE marked: EN61326-2-3: 2006 |
||||
| Mass | 400 g |
400 g |
500 g |
700 g |
1100 g |
Notes:
*1. The unit L/min (normal) refers to the volumetric flow rate adjusted for 0 ˚C, 101.325 kPa.
*2. Flow is displayed as a negative value without changing the setting.
*3. Indication value and integrated pulse output can be displayed and output without changing the setting, but 4–20 mA output requires a change of the span setting.
*4. The guaranteed accuracy range figures are ±3 % FS.
*5. Integrated pulse output specifications (selectable by settings)
- Pulse width: 50 ms, 250 ms, 500 ms
- Pulse weight:
Model No. |
Pulse weight (L/pulse) |
|---|---|
MCF008 |
10, 100, 1000 |
MCF015 |
10, 100, 1000 |
MCF025 |
10, 100, 1000 |
MCF040 |
100, 1000, 10000 |
MCF050 |
100, 1000, 10000 |
| Power | Cable properties | Cable length | Model No. | Lead color |
|---|---|---|---|---|
DC |
Oil resistant, bend-tolerant UL2464 Flame-resistant cable EN-compliant. |
2 m |
PA5-4ISX2MK-E |
1: Brown. 2: White. 3: Blue. 4: Black. |
5 m |
PA5-4ISX5MK-E |
1: Brown. 2: White. 3: Blue. 4: Black. |
Note: Types other than the above are available. Please contact our sales representatives.
Catalog (mcf_e)
User's Manual for Installation (CP-UM-5498JE)
User's Manual for Installation and Configuration (CP-SP-1276E)
Measurement Module Replacement Manual (CP-UM-5527JE)
USA Model User's Manual for Installation and Configuration (CP-SP-1293E)
NPT Model User's Manual for Installation (CP-UM-5573E)
NPT Model Measurement Module Replacement Manual (CP-UM-5593E)
* In information issued before March 2012, there may be cases where the former corporate name is used.