No. SS2-8113-0310 Azbil Corporation - 14 - Contoured type metal seat (%CC, LCC) : Graphite packing “P6610CH+P8590” (+500 to +566 °C) Valves with type VP actuator Note) 1) When a backup system for pressure drop at the air source is used, select the allowable differential pressure from whichever is lower constant supplied air pressure or backup system set pressure (trip pressure). 2) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34-1981 or JIS B2201-1984. 3) The upper figures denote the operating allowable differential pressure. The lower denote allowable differential pressure at full closure. Table 16 Air-to-close and Air-to-open Actuator Model No. Supply pressure kPa{Kgf/cm2} Differential pressure kPa {kgf/cm2} 2. 3 4 6 8 1 1. 1. 1. 1. 2 1. 2 2. 2. 3 4 3 4 5 VP5 290 {3.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3590 {36.6} 3590 {36.6} 2530 {25.7} 1420 {14.4} 2530 {25.7} 1420 {14.4} 910 9810 {9.2} {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 5700 {58.1} 9810 {100} 5700 {58.1} 390 {4.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3800 {38.7} 2130 {21.7} 3800 {38.7} 2130 {21.7} 1360 9810 {13.8} {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 8550 {87.1} 9810 {100} 8550 {87.1} 5380 {54.8} 5380 {54.8} 490 {5.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2850 {29.0} 3920 {40.0} 2850 {29.0} 1820 9810 {18.5} {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 7180 {73.2} 7180 {73.2} 5070 {51.6} 5070 {51.6} VP6 290 {3.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2410 {24.5} 3920 {40.0} 2410 {24.5} 1540 9810 {15.7} {100} 9670 {98.6} 6090 {62.1} 6090 {62.1} 4300 {43.8} 4300 {43.8} 390 {4.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3620 {36.9} 3920 {40.0} 3620 {36.9} 2320 9810 {23.6} {100} 9810 {100} 9140 {93.2} 9140 {93.2} 6450 {65.7} 6450 {65.7} 490 {5.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3090 9810 {31.5} {100} 9810 {100} 9810 {100} 9810 {100} 8600 {87.6} 4830 {49.2} 8600 {87.6} 4830 {49.2} VP7 290 {3.0} 3920 {40.0} 3920 {40.0} 3710 {37.8} 3920 {40.0} 3710 {37.8} 2370 9360 {24.1} {95.4} 6600 {67.3} 6600 {67.3} 390 {4.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3560 9810 {36.3} {100} 9810 {100} 5570 {56.7} 9810 {100} 5570 {56.7} 490 {5.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 9810 {100} 9810 {100} 7430 {75.7} 9810 {100} 7430 {75.7} 4750 {48.4} |