No. SS2-8113-0320 Azbil Corporation - 12 - Contoured-type metal seat (%CF, LCF, %C, LC): Graphite packing “P6610CH+M8590” (+500 to +566 °C) Valves with type PSA1, HA or VA actuator Note) 1) ..: Positioner is necessary. 2) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34-1981 or JIS B2201-1984. 3) The upper figures denote the operating allowable differential pressure. The lower denote allowable differential pressure at full closure. 4) *1…Applicable to valve sizes of 2. to 4 inches, *2 …Applicable to valve size of 6 inches, *3 …Applicable to valve size of 8 inches. Table 14 Air-to-close Actuator Model No. Supply pressure kPa{kgf/cm2} Spring range kPa{kgf/cm2} Positioner Differential Pressure (by port size(inches)) kPa {kgf/cm2} 1 1. 1. 2 2. 3 4 5 6 HA2D 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3170 {32.3} 1830 {18.6} 1150 {11.7} 810 {8.2} 450 5100 {4.5} {52.0} 4470 {45.5} HA3D 3920 {40.0} 3920 {40.0} 3920 {40.0} 3240 {33.0} 2040 {20.8} 1440 {14.6} 810 {8.2} 510 {5.2} 310 5100 {3.1} {52.0} 5100 {52.0} 5100 {52.0} HA4D 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3660 {37.3} 2580 {26.3} 1450 {14.7} 930 {9.4} 560 5100 {5.7} {52.0} 5100 {52.0} 5100 {52.0} 5100 {52.0} VA5D 270 {2.8} 40 to 200 {0.4 to 2.0} 5100 {52.0} 5100 {52.0} 3920 {40.0} 2380 {24.2} 1500 {15.2} 1050 {10.7} 590 {6.0} 380 {3.8} 230 4120 {2.3} {42.0} Table 15 Air-to-open Actuator Model No. Supply pressure kPa{kgf/cm2} Spring range kPa{kgf/cm2} Positioner Differential Pressure (by port size(inches)) kPa {kgf/cm2} 1 1. 1. 2 2. 3 4 5 6 HA2R 270 {2.8} 80 to 240 {0.8 to 2.4} .. 2900 {29.5} 1770 {18.0} 1250 {12.7} 720 {7.3} 450 {4.5} 320 {3.2} 180 {1.8} HA3R 3920 {40.0} 3140 {32.0} 2230 {22.7} 1280 {13.0} 810 {8.2} 570 {5.8} 320 {3.2} 200 {2.0} 120 5100 {1.2} {52.0} HA4R 3920 {40.0} 3920 {40.0} 3920 {40.0} 2430 {24.7} 1530 {15.6} 1080 {11.0} 600 {6.1} 390 {3.9} 230 5100 {2.3} {52.0} 5100 {52.0} 4220 {43.0} VA5R 3920 {40.0} 3920 {40.0} 3920 {40.0} 3040 {30.9} 1910 {19.4} 1350 {13.7} 760 {7.7} 480 {4.8} 290 5100 {2.9} {52.0} 5100 {52.0} 5100 {52.0} PSA6R 400 {4.0} *1 200 to 340 {2.0 to 3.5} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2320 5100 {23.6} {52.0} 5100 {52.0} 5100 {52.0} 5100 {52.0} 5100 {52.0} 4130 {42.1} 500 {5.0} *2 200 to 390 {2.0 to 4.0} 2320 {23.6} 1480 {15.0} 900 {9.1} 400 {4.0} *3 200 to 340 {2.0 to 3.5} 1480 {15.0} 900 {9.1} |