- 1 - 8th edition No. SS2-8113-0400 OVERVIEW Model HPS Top-Guided High-Pressure Single Seated Control Valves are design for high temperature, high pressure services. The compact valve body, habing a Sshade flow passage that features low pressure loss, allows a large flow capasity and rangeability. The valve plug is highly vibration-resistant as it is held by a top guide section which has a large slideing area. The flow shut-off performance complies with the ANSI Standard. The actuator integrated with simplest mechanisms utilizes a compact yet powerful diaphragm actuator loaded with multiple springs. The HPS Valves are widely applicable for reliable control of high temperature, high pressure process lines. SPECIFICATIONS Body Type: Straight through, cast globe valve Nominal size: 1, 1., 2, 3 inches Pressure rating: JIS 63K ANSI Class 900, 1500, 2500 JPI Class 900, 1500, 2500 End connection Flanged end; Welded end; SW (1 to 3 inches), BW (3 inches) Material For body/trim material combinations and operating temperature ranges, refer to Table1. Bonnet: Plain bonnet (-5 to 230°C) Extension bonnet Type 1 (230 to 566°C) Note) Take care not to exceed the operating temperature ranges specified for respective materials. Gland type: Bolted gland Packing/grease: Grease provided When asbestos yarn, graphite packing, and others Gasket Type; Combination of serrated type and flat type Material; Stainless steel (SUS316) or others Connection type Pressure rating Applicable standard RF JIS63K JIS B2210-1984 ANSI Class 900, 1500, 2500 ANSI B16.5-1981 JPI Class 900, 1500, 2500 JPI-7S-15-1993 RJ ANSI Class 900, 1500, 2500 ANSI B16.5-1981 JPI Class 900, 1500, 2500 JPI-7S-15-1993 Trim Valve plug -Metal seat Single seated, Contoured-type plug Equal percentage (%C), Linear (LC) Material For body/trim material combinations and operating temperature ranges, refer to Table1. Actuator Type Single acting diaphragm actuator (Type HA or VA5) Spring Type piston actuator (Type PSA6) Double acting piston actuator (Type VP) Action: Direct or reverse action Diaphragm Type HA : Cloth embedded ethylene propylene rubber Type VA : Cloth embedded chloroprene rubber Spring range Type HA, Type VA5 20 to 98 kPa {0.2 to 1.0 kgf/cm2}, 40 to 200 kPa {0.4 to 2.0 kgf/cm2}, 80 to 240 kPa {0.8 to 2.4 kgf/cm2} CV3000 Series Top-Guided High-Pressure Single Seated Control Valves Model HPS 1 8 Specifications are subject to change without notice. “This product is designed for general industrial use.” |