【DO!BOOK・ページリンク】 cv-01 132 / 168 10秒後にBOOKのページに移動します |
|
Azbil Corporation No. SS2-8113-0400 - 9 - Contoured-type metal seat (%C, LC) : PTFE packing Valves with type HA or VA actuator Table 12 Air-to-close Rating Actuator Model No. Supply pressure kPa {kgf/cm2} Spring Range kPa {kgf/cm2} Differential Pressure (by Port size(inch)) kPa {kgf/cm2} Cv<=4.0 Cv=6.3 Cv=12 1 . inch 1 . inch 2 inches 2 . inches 3 inches JIS63K ANSI 900, 1500 JPI 900, 1500 HA3D 270 {2.8} 40 to 200 {0.4 to 2.0} 16000 {163.0} 15800 {161.0} 10000 {102.0} 4900 {50.0} 3140 {32.0} 1760 {18.0} 9800 {10.0} 6900 {7.0} 14900 {152.0} 14600 {149.0} 9020 {92.0} 4120 {42.0} 2650 {27.0} 1370 {14.0} 6900 {7.0} 3900 {4.0} 290 {3.0} 20300 {207.0} 20100 {205.0} 12700 {130.0} 6280 {64.0} 4120 {42.0} 2350 {24.0} 1370 {14.0} 8800 {9.0} 19200 {196.0} 18800 {192.0} 11800 {120.0} 5590 {57.0} 3530 {36.0} 1860 {19.0} 9810 {10.0} 5900 {6.0} 340 {3.5} 25900 {264.0} 25900 {264.0} 19600 {200.0} 9810 {100.0} 6470 {66.0} 3730 {38.0} 2260 {23.0} 1570 {16.0} 25900 {264.0} 25900 {264.0} 18600 {190.0} 9020 {92.0} 5580 {60.0} 3330 {34.0} 1860 {19.0} 1270 {13.0} 390 {4.0} 25900 {264.0} 13200 {135.0} 8920 {91.0} 5200 {53.0} 3140 {32.0} 2160 {22.0} 25500 {260.0} 12600 {128.0} 8340 {85.0} 4710 {48.0} 2740 {28.0} 1860 {19.0} HA4D 270 {2.8} 40 to 200 {0.4 to 2.0} 17900 {183.0} 8920 {91.0} 5980 {61.0} 3430 {35.0} 2060 {21.0} 1370 {14.0} 17000 {173.0} 8240 {84.0} 5390 {55.0} 2940 {30.0} 1670 {17.0} 1080 {11.0} 290 {3.0} 22600 {231.0} 11400 {116.0} 7550 {77.0} 4410 {45.0} 2650 {27.0} 1860 {19.0} 21700 {221.0} 10700 {109.0} 6960 {71.0} 3920 {40.0} 2260 {23.0} 1570 {16.0} 340 {3.5} 25900 {264.0} 17400 {177.0} 1170 {119.0} 6860 {70.0} 4120 {42.0} 2940 {30.0} 25900 {264.0} 16700 {170.0} 11100 {113.0} 6370 {65.0} 3820 {39.0} 2650 {27.0} 390 {4.0} 23400 {239.0} 15800 {161.0} 9320 {95.0} 5690 {58.0} 4020 {41.0} 22800 {232.0} 15200 {155.0} 8820 {90.0} 5300 {54.0} 3730 {38.0} VA5D 260 {2.6} 20 to 98 {0.2 to 1.0} 25800 {263.0} 17400 {177.0} 10200 {104.0} 6180 {63.0} 4410 {45.0} 25000 {255.0} 16800 {171.0} 9810 {100.0} 5880 {60.0} 4120 {42.0} 270 {2.8} 25900 {264.0} 19600 {200.0} 11600 {118.0} 7060 {72.0} 5000 {51.0} 25900 {264.0} 19000 {194.0} 11200 {114.0} 6670 {68.0} 4170 {48.0} ANSI 2500 JPI 2500 HA3D 270 {2.8} 40 to 200 {0.4 to 2.0} 16000 {163.0} 15800 {161.0} 10000 {102.0} 10000 {102.0} 4900 {50.0} 2450 {25.0} 1760 {18.0} 9800 {10.0} 14900 {152.0} 14600 {149.0} 9020 {92.0} 9020 {92.0} 4120 {42.0} 1960 {20.0} 1370 {14.0} 6900 {7.0} 290 {3.0} 20300 {207.0} 20100 {205.0} 12700 {130.0} 12700 {130.0} 6280 {64.0} 3240 {33.0} 2350 {24.0} 1370 {14.0} 19200 {196.0} 18800 {192.0} 11800 {120.0} 11800 {120.0} 5590 {57.0} 2740 {28.0} 1860 {19.0} 9800 {10.0} 340 {3.5} 31000 {316.0} 30800 {314.0} 19600 {200.0} 19600 {200.0} 9810 {100.0} 5100 {52.0} 3730 {38.0} 2260 {23.0} 29900 {305.0} 29500 {301.0} 18600 {190.0} 18600 {190.0} 9020 {92.0} 4610 {47.0} 3330 {34.0} 1860 {19.0} 390 {4.0} 41700 {425.0} 41500 {423.0} 26500 {270.0} 26500 {270.0} 13200 {135.0} 7060 {72.0} 5200 {53.0} 3140 {32.0} 40600 {414.0} 40200 {410.0} 25500 {260.0} 25500 {260.0} 12600 {128.0} 6570 {67.0} 4710 {48.0} 2740 {28.0} HA4D 270 {2.8} 40 to 200 {0.4 to 2.0} 17900 {183.0} 17900 {183.0} 8920 {91.0} 4710 {48.0} 3430 {35.0} 2060 {21.0} 17000 {173.0} 17000 {173.0} 8240 {84.0} 4220 {43.0} 2940 {30.0} 1670 {17.0} 290 {3.0} 22700 {231.0} 22700 {231.0} 11400 {116.0} 5980 {61.0} 4410 {45.0} 2650 {27.0} 21700 {221.0} 21700 {221.0} 10700 {109.0} 5490 {56.0} 3920 {40.0} 2260 {23.0} 340 {3.5} 34400 {351.0} 34400 {351.0} 17400 {177.0} 9320 {95.0} 6860 {70.0} 4120 {42.0} 33400 {341.0} 33400 {341.0} 16700 {170.0} 8730 {89.0} 6370 {65.0} 3820 {39.0} 390 {4.0} 43100 {440.0} 43100 {440.0} 23400 {239.0} 12600 {128.0} 9320 {95.0} 5690 {58.0} 43100 {440.0} 43100 {440.0} 22800 {232.0} 12100 {123.0} 8820 {90.0} 5300 {54.0} VA5D 260 {2.6} 20 to 98 {0.2 to 1.0} 25800 {263.0} 13800 {141.0} 10200 {104.0} 6180 {63.0} 25000 {255.0} 13300 {136.0} 9810 {100.0} 5880 {60.0} 270 {2.8} 29000 {296.0} 15600 {159.0} 11600 {118.0} 7060 {72.0} 28300 {289.0} 15100 {154.0} 11200 {114.0} 6670 {68.0} 1 8 |