No. SS2-8113-0400 Azbil Corporation - 10 - Note) 1) “ ” show a model with standard actuator. 2) Positioner is employed in general. 3) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16.34-1981 or JIS B2201-1984. 4) Take care not to cause the inlet pressure (P1) to exceed allowable differential pressure at valve-close. 5) Allowable differential pressure limit differs depending on valve seat leakage volume. Figures in the upper portion of the column denote pressure under a leakage rate of 0.01%. Those on the lower side denote pressure under a leakage rate of 0.001%. 6) *1 is applicable to valve size 1 inch; Cv value 0.25 to 0.63. *2 is applicable to valve size 1 inch; Cv value 1.0 to 12, size 1. to 2 inches. *3 is applicable to valve size 3 inches. *4 Supply pressure is configurable. Please specify the supply pressure. Table 13 Air-to-open Rating Actuator Model No. Supply pressure kPa {kgf/cm2} Spring Range kPa {kgf/cm2} Differential Pressure (by Port size(inch)) kPa {kgf/cm2} Cv<=4.0 Cv=6.3 Cv=12 1 . inch 1 . inch 2 inches 2 . inches 3 inches JIS63K ANSI 900, 1500 JPI 900, 1500 HA3R 260 - 390 {2.6 - 4.0} *4 80 to 240 {0.8 to 2.4} 16000 {163.0} 15800 {161.0} 10000 {102.0} 4900 {50.0} 3140 {32.0} 1760 {18.0} 9800 {10.0} 6900 {7.0} 14900 {152.0} 14600 {149.0} 9020 {92.0} 4120 {42.0} 2650 {27.0} 1370 {14.0} 6900 {7.0} 3900 {4.0} HA4R 80 to 240 {0.8 to 2.4} 18300 {187.0} 18100 {185.0} 17900 {183.0} 8920 {91.0} 5980 {61.0} 3430 {35.0} 2060 {21.0} 1370 {14.0} 17600 {180.0} 17400 {177.0} 17000 {173.0} 8240 {84.0} 5390 {55.0} 2940 {30.0} 1670 {17.0} 1080 {11.0} VA5R 250 - 270 {2.5 - 2.8} *4 80 to 240 {0.8 to 2.4} 12400 {127.0} 8340 {85.0} 4900 {50.0} 2940 {30.0} 2060 {21.0} 11800 {120.0} 7750 {79.0} 4410 {45.0} 2550 {26.0} 1760 {18.0} PSA6 300 {3.0}*1 200 to 255 {2.0 to 2.6} 25900 {264.0} 25900 {264.0} 25900 {264.0} 25300 {258.0} 17100 {174.0} 10000 {102.0} 6080 {62.0} 4310 {44.0} 350 {3.5}*2 200 to 295 {2.0 to 3.0} 25900 {264.0} 25900 {264.0} 25900 {264.0} 24600 {251.0} 16500 {168.0} 9610 {98.0} 5780 {59.0} 4020 400 {41.0} {4.0}*3 200 to 340 {2.0 to 3.5} ANSI 2500 JPI 2500 HA3R 260 - 390 {2.6 - 4.0} *4 80 to 240 {0.8 to 2.4} 16000 {163.0} 15800 {161.0} 10000 {102.0} 10000 {102.0} 4900 {50.0} 2450 {25.0} 1760 {18.0} 9800 {10.0} 14900 {152.0} 14600 {149.0} 9020 {92.0} 9020 {92.0} 4120 {42.0} 1960 {20.0} 1370 {14.0} 6900 {7.0} HA4R 80 to 240 {0.8 to 2.4} 18300 {187.0} 18100 {185.0} 17900 {183.0} 17900 {183.0} 8900 {91.0} 4710 {48.0} 3430 {35.0} 2060 {21.0} 17600 {180.0} 17400 {177.0} 17000 {173.0} 17000 {173.0} 8200 {84.0} 4220 {43.0} 2940 {30.0} 1670 {17.0} VA5R 260 - 270 {2.6 - 2.8} *4 80 to 240 {0.8 to 2.4} 12400 {127.0} 6670 {68.0} 4900 {50.0} 2940 {30.0} 11800 {120.0} 6080 {62.0} 4410 {45.0} 2550 {26.0} PSA6 300 {3.0}*1 200 to 255 {2.0 to 2.6} 32300 {329.0} 32200 {328.0} 32100 {327.0} 32100 {327.0} 25300 {258.0} 13500 {138.0} 10000 {102.0} 6080 {62.0} 350 {3.5}*2 200 to 295 {2.0 to 3.0} 31900 {325.0} 31700 {323.0} 31400 {320.0} 31400 {320.0} 24600 {251.0} 13000 {133.0} 7650 {78.0} 5780 400 {59.0} {4.0}*3 200 to 340 {2.0 to 3.5} |