No. SS2-AGV200-0001 Azbil Corporation - 10 - Valve seat leakage, Class IV: 0.01% of the rated Cv value Table 13 Model AGVB nominal size 1/2, 3/4 and 1 inch Note that the allowable differential pressure varies with the rated Cv value you have selected. Air-to-close Note) 1. In the case of using positioners, please the setting of supply pressure with pressure regulator. 2. The maximum allowable differential pressures must not exceed the maximum working pressures specified by JISB2201-1984, ANSIB16.34-1981, and JPI-7S-65-831. Table 14 Model AGVB nominal size 1., 2, 2., 3 and 4 inches Note that the allowable differential pressure varies with the port size (inches) you have selected. Air-to-close Note) 1. In the case of using positioners, please the setting of supply pressure with pressure regulator. 2.The maximum allowable differential pressures must not exceed the maximum working pressures specified by JISB2201-1984, ANSIB16.34-1981, and JPI-7S-65-831. Nominal size inch Actuator Supply pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Differential pressure (by Cv value) kPa {kgf/cm2} 0.1 0.16 0.25 0.4 0.63 1.0 1.6 2.5 4.0 6.3 8.0 10 14 1/2 3/4 1 PSA1D 140{1.4} 20 to 98 {0.2 to 1.0} 1380 {14.1} 1030 {10.5} 160{1.6} 20 to 98 {0.2 to 1.0} 1960 {20.0} 1860 {18.9} 390{4.0} 80 to 240 {0.8 to 2.4} PSA2D 140{1.4} 20 to 98 {0.2 to 1.0} -- -- -- -- 160{1.6} 20 to 98 {0.2 to 1.0} -- -- -- -- -- Nominal size inches Actuator Supply pressure kPa {kgf/cm2} Spring range kPa{kgf/cm2} Differential pressure (by port size (inches)) kPa{kgf/cm2} 1 1. 1. 2 2. 3 4 1. 2 PSA1D 140 {1.4} 20 to 98 {0.2 to 1.0} 1030 {10.5} 640 {6.5} 430 {4.4} 260 {2.6} -- -- -- 160 {1.6} 20 to 98 {0.2 to 1.0} 1860 {18.9} 1150 {11.7} 780 {7.9} 460 {4.7} -- -- -- 390 {4.0} 80 to 240 {0.8 to 2.4} 1500 {15.3} -- -- -- PSA2D 140 {1.4} 20 to 98 {0.2 to 1.0} 1960 {20.0} 1230 {12.6} 840 {8.5} 500 {5.1} -- -- -- 160 {1.6} 20 to 98 {0.2 to 1.0} 1510 {15.4} 900 {9.2} -- -- -- 390 {4.0} 80 to 240 {0.2 to 1.0} -- -- -- 1960 {20.0} -- -- -- PSA3D 140 {1.4} 20 to 98 {0.2 to 1.0} -- 1960 {20.0} 1490 {15.1} 890 {9.0} -- -- -- 160 {1.6} 20 to 98 {0.2 to 1.0} -- -- 1960 {20.0} 1600 {16.3} -- -- -- PSA4D 140 {1.4} 20 to 98 {0.2 to 1.0} -- -- 1530 {15.6} -- -- -- 160 {1.6} 20 to 98 {0.2 to 1.0} -- -- -- 1960 {20.0} -- -- -- 2. 3 4 PSA3D 140 {1.4} 20 to 98 {0.2 to 1.0} -- -- 1490 {15.1} 890 {9.0} 550 {5.6} 390 {4.0} 220 {2.3} 160 {1.6} 20 to 98 {0.2 to 1.0} -- -- 1960 {20.0} 1600 {16.3} 990 {10.0} 710 {7.2} 400 {4.1} 390 {4.0} 80 to 240 {0.8 to 2.4} -- -- 1290 {13.1} PSA4D 140 {1.4} 20 to 98 {0.2 to 1.0} -- -- 1530 {15.6} 950 {9.6} 680 {6.9} 380 {3.9} 160 {1.6} 20 to 98 {0.2 to 1.0} -- -- 1960 {20.0} 1700 {17.4} 1230 {12.5} 700 {7.0} 390 {4.0} 80 to 240 {0.8 to 2.4} -- -- -- -- -- -- 1960 {20.0} |