Azbil Corporation No. SS2-8110-0300 - 5 - Note) 1. * The allowable differential pressure for 40 to 200 kPa {0.4 to 2.0 kgf/cm2} spring range are the same as for 40 to 120 kPa {0.4 to 1.2 kgf/cm2} spring. 2. The figures inside bold line are for standard actuator. 3. Positioner; ..... without, ..... Preferably with, .....with Table 3 Air-to-open Actuator model No. Supply pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Positioner Differential pressure kPa {kgf/cm2} Port size (inches) 1 1. 1. 2 2. 3 4 5 6 8 10 12 VA1R 140 {1.4} 20 to 98 {0.2 to 1.0} .. or .. 740 {7.5} 460 {4.7} 300 {3.1} 180 {1.8} --- --- --- 40 to 120 {0.4 to 1.2} * .. 2160 {22.0} 1370 {14.0} 910 {9.3} 550 {5.6} --- --- --- 270 {2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3240 {33.0} 2060 {21.0} 1270 {13.0} --- --- --- VA2R 140 {1.4} 20 to 98 {0.2 to 1.0} .. or .. 981 {10.0} 670 {6.8} 440 {4.5} 250 {2.6} 160 {1.6} 110 {1.1} 60 {0.6} 40 to 120 {0.4 to 1.2} * .. 3140 {32.0} 1960 {20.0} 1270 {13.0} 780 {8.0} 490 {5.0} 340 {3.5} 200 {2.0} 270 {2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3040 {31.0} 1760 {18.0} 1080 {11.0} 810 {8.3} 460 {4.7} --- --- VA3R 140 {1.4} 20 to 98 {0.2 to 1.0} .. or .. 1670 {17.0} 1080 {11.0} 720 {7.4} 430 {4.4} 260 {2.7} 190 {1.9} 110 {1.1} 70 {0.7} 40 {0.4} 40 to 120 {0.4 to 1.2} * .. 3920 {40.0} 3330 {34.0} 2160 {22.0} 1270 {13.0} 800 {8.2} 580 {5.9} 320 {3.3} 200 {2.1} 140 {1.4} 270 {2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3040 {31.0} 1860 {19.0} 1270 {13.0} 760 {7.8} 490 {5.0} 330 {3.4} VA4R 140 {1.4} 20 to 98 {0.2 to 1.0} .. or .. --- --- --- --- 370 {3.8} 260 {2.7} 150 {1.5} 98 {1.0} 60 {0.6} 38 {0.39} --- --- 40 to 120 {0.4 to 1.2} * .. --- --- --- --- 1080 {11.0} 810 {8.3} 450 {4.6} 290 {3.0} 200 {2.0} 110 {1.1} --- --- 270 {2.8} 80 to 240 {0.8 to 2.4} .. --- --- --- --- 2650 {27.0} 1860 {19.0} 981 {10.0} 690 {7.0} 470 {4.8} 260 {2.7} --- --- VA5R 140 {1.4} 20 to 98 {0.2 to 1.0} .. or .. --- --- --- --- --- --- --- 130 {1.3} 90 {0.9} 52 {0.53} 33 {0.34} 22 {0.23} 40 to 120 {0.4 to 1.2} * .. --- --- --- --- --- --- --- 400 {4.0} 270 {2.8} 160 {1.6} 98 {1.0} 70 {0.71} 270 {2.8} 80 to 240 {0.8 to 2.4} .. --- --- --- --- --- --- --- 930 {9.5} 650 {6.6} 360 {3.7} 220 {2.3} 160 {1.6} PSA6R 500 {5.0} 200 to 340 {2.0 to 3.5} .. --- --- --- --- 3920 {40.0} 3920 {40.0} 2940 {30.0} --- --- 830 {8.5} --- --- 200 to 390 {2.0 to 4.0} .. --- --- --- --- --- --- --- 1860 {19.0} 1240 {12.6} --- 540 {5.5} 370 {3.8} 1 9 |