Azbil Corporation No. SS2-AGV200-0001 - 15 - Valve seat leakage, Class V and Class IV-S1: high shutoff model: metal seat Table 19 Model AGVB nominal size 1/2, 3/4 and 1 inch Note that the allowable differential pressure varies with the rated Cv value you have selected. Air-to-open Note) 1. In the case of using positioners, please the setting of supply pressure with pressure regulator. 2. The maximum allowable differential pressures must not exceed the maximum working pressures specified by JISB2201-1984, ANSIB16.34-1981, and JPI-7S-65-831. Table 20 Model AGVB nominal size 1., 2, 2., 3 and 4 inches Note that the allowable differential pressure varies with the port size (inches) you have selected Air-to-open Note) 1. In the case of using positioners, please the setting of supply pressure with pressure regulator. 2. The maximum allowable differential pressures must not exceed the maximum working pressures specified by JISB2201-1984, ANSIB16.34-1981, and JPI-7S-65-831. Table 21 Model AGVB nominal size 1/2, 3/4 and 1 inch Note that the allowable differential pressure varies with the rated Cv value you have selected. Air-to-close Note) 1. In the case of using positioners, please the setting of supply pressure with pressure regulator. 2. The maximum allowable differential pressures must not exceed the maximum working pressures specified by JISB2201-1984, ANSIB16.34-1981, and JPI-7S-65-831. Nominal size (inch) Actuator Supply pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Differential pressure (by Cv value) kPa{kgf/cm2} 0.1 0.16 0.25 0.4 0.63 1.0 1.6 2.5 4.0 6.3 8.0 10 14 1/2 3/4 1 PSA1R 270{2.8} 80 to 240 {0.8 to 2.4} 1960 {20.0} Nominal size (inches) Actuator Supply pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Differential pressure (by port size (inches)) kPa{kgf/cm2} 1 1. 1. 2 2. 3 4 1. 2 PSA1R 270 {2.8} 80 to 240 {0.8 to 2.4} 1960 {20.0} 1110 {11.3] 660 {6.7} 270 {2.8} -- -- -- PSA2R 270 {2.8} 80 to 240 {0.8 to 2.4} -- 1960 {20.0} 1550 {15.8} 810 {8.2} -- -- -- PSA3R 270 {2.8} 80 to 240 {0.8 to 2.4} -- -- 1960 {20.0} 1660 {16.9} -- -- -- PSA4R 270 {2.8} 80 to 240 {0.8 to 2.4} -- -- -- 1960 {20.0} -- -- -- 2. 3 4 PSA3R 270 {2.8} 80 to 240 {0.8 to 2.4} -- -- 1960 {20.0} 1660 {16.9} 910 {9.3} 570 {5.8} 190 {2.0} PSA4R 270 {2.8} 80 to 240 {0.8 to 2.4} -- -- -- 1960 {20.0} 1790 {18.2} 1200 {12.3} 550 {5.6} PSA6R 260 {2.6} 100 to 180 {1.0 to 1.8} -- -- -- -- 1960 {20.0} 1850 {18.9} 910 {9.3} 400 {4.0} 200 to 340 {2.0 to 3.5} -- -- -- -- -- 1960 {20.0} Nominal size (inch) Actuator Supply pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Differential pressure (by Cv value) kPa{kgf/cm2} 0.1 0.16 0.25 0.4 0.63 1.0 1.6 2.5 4.0 6.3 8.0 10 14 1/2 3/4 1 PSA1D 160 {1.6} 20 to 98 {0.2 to 1.0} 1960 {20.0} 1640 {16.8} 1150 {11.7} 390 {4.0} 80 to 240 {0.8 to 2.4} PSA2D 160 {1.6} 20 to 98 {0.2 to 1.0} -- -- -- -- 1 1 |