No. SS2-AGV200-0001 Azbil Corporation - 20 - Valve seat leakage, Class VI: high shutoff model: soft seat Table 30 Model AGVB nominal size 1., 2, 2., 3, and 4 inches Note that the allowable differential pressure varies with the port size (inches) you have selected. Air-to-close Note) 1. In the case of using positioners, please the setting of supply pressure with pressure regulator. 2. The maximum allowable differential pressures must not exceed the maximum working pressures specified by JISB2201-1984, ANSIB16.34-1981, and JPI-7S-65-831. Table 31 Model AGVM nominal size 1/2, 3/4 and 1 inch Note that the allowable differential pressure varies with the rated Cv value you have selected. Air-to-open Note) 1. In the case of using positioners, please the setting of supply pressure with pressure regulator. 2. The maximum allowable differential pressures must not exceed the maximum working pressures specified by JISB2201-1984, ANSIB16.34-1981, and JPI-7S-65-831. 3. In the differential pressure column, upper figures show normal differential pressures and lower figures differential pressures when the valve is fully closed. Nominal size (inches) Actuator Supply pressure kPa {kgf/cm2} Spring range kPa {kgf/ cm2} Differential pressure (by port size (inches)) kPa{kgf/cm2} 1 1. 1. 2 2. 3 4 1. 2 PSA1D 390 {4.0} 80 to 240 {0.8 to 2.4} 1960 {20.0} 1860 {19.0} 1390 {14.2} 730 {7.4} -- -- -- PSA2D 140 {1.4} 20 to 98 {0.2 to 1.0} 790 {8.1} 310 {3.2} -- -- -- -- -- 160 {1.6} 20 to 98 {0.2 to 1.0} 1750 {17.8} 1170 {11.9} 680 {6.9} 280 {2.9} -- -- -- 390 {4.0} 80 to 240 {0.8 to 2.4} -- 1960 {20.0} 1860 {18.0} -- -- PSA3D 140 {1.4} 20 to 98 {0.2 to 1.0} 1960 {20.0} 1410 {1.41} 880 {9.0} 400 {4.1} -- -- -- 160 {1.6} 20 to 98 {0.2 to 1.0} 1710 {17.4} 1050 {10.7} -- -- -- 390 {4.0} 80 to 240 {0.8 to 2.4} -- -- -- 1960 {20.0} -- -- -- PSA4D 140 {1.4} 20 to 98 {0.2 to 1.0} 1960 {20.0} 1320 {13.5} -- -- -- 160 {1.6} 20 to 98 {0.2 to 1.0} -- -- -- -- -- 2. 3 4 PSA3D 140 {1.4} 20 to 98 {0.2 to 1.0} -- -- 880 {9.0} 400 {4.1} 150 {1.5} -- -- 160 {1.6} 20 to 98 {0.2 to 1.0} -- -- 1710 {17.4} 1050 {10.7} 550 {5.6} 340 {3.5} 110 {1.1} 390 {4.0} 80 to 240 {0.8 to 2.4} -- -- 1710{ 17.4} 960 {9.8} PSA4D 140 {1.4} 20 to 98 {0.2 to 1.0} -- -- 1960 {20.0} 1320 {13.5} 730 {7.4} 470 {4.8} 190 {1.9} 160 {1.6} 20 to 98 {0.2 to 1.0} -- -- 1410 {14.4} 980 {10.0} 480 {4.9} 390 {4.0} 80 to 240 {0.8 to 2.4} -- -- -- -- 1960 {20.0} 1820 {18.6} Nominal size (inch) Actuator Supply pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Differential pressure (by Cv value) kPa{kgf/cm2} 0.1 0.16 0.25 0.4 0.63 1.0 1.6 2.5 4.0 6.3 8.0 10 14 1/2 3/4 1 PSA1R 270{2.8} 80 to 240 {0.8 to 2.4} 1960 {20.0} 1440 {14.7} 1030 2940 {10.5} {30.0} 2850 {29.1} 2140 {21.8} PSA2R 270{2.8} 80 to 240 {0.8 to 2.4} -- -- 1960 {20.0} 2940 {30.0} 2450 {25.0} |