【DO!BOOK・ページリンク】 cv-01 35 / 168 10秒後にBOOKのページに移動します |
|
No. SS2-8113-0200 Azbil Corporation - 4 - Note) “ ” shows standard combination of value body and trim materials. Note) “..” denotes production ranges. Table 1 Body/trim material combinations and operating temperature ranges (°C) Body material Trim material JIS SCPH2 SCPH21 SCPH61 SCPL1 SCS11 SCS13A SCS14A SCS16A SCS19A ASTM A216WCB A217WC6 A217C5 A352LCB - A351CF8 A351CF8M A351CF3M A351CF3 JIS SUS304 -5 to +300 -45 to +300 -196 to +300 JIS SUS316 -5 to +300 -45 to +300 -196 to +300 -196 to +300 JIS SUS304L -45 to +300 -196 to +300 -196 to +300 JIS SUS316L -5 to +300 -5 to +300 -45 to +300 -196 to +300 -196 to +300 -196 to +300 -196 to +300 JIS SUS440C -5 to +425 -5 to +425- -5 to 425 JIS SUS329J1 -5 to +300 -196 to +300 JIS SUS304 Stellite -5 to +425 -5 to +550- -5 to 566 -45 to +350 -196 to +550 JIS SUS304 Stellite face -5 to +425 -5 to +550- -5 to 566 -45 to +350 -196 to +550 JIS SUS316 Stellite -5 to +425 -5 to +550- -5 to 566 -45 to +350 -196 to +550 -196 to +550 JIS SUS316 Stellite face -5 to +425 -5 to +550- -5 to 566 -45 to +350 -196 to +550 -196 to +550 JIS SUS304L Stellite -45 to +350 -196 to +550 -196 to +450 JIS SUS316L Stellite -45 to +350 -196 to +450 -196 to +450 -196 to +450 -196 to +450 JIS SUS329J1 Stellite -50 to +550 -196 to +550 JIS SUS304 Soft seat -5 to +230 -45 to +230 -80 to +230 JIS SUS316 Soft seat -5 to 230 -45 to +230 -80 to +230 -80 to +230 JIS SUS316L Soft seat -45 to +230 -80 to +230 -80 to +230 -80 to +230 -80 to +230 JIS SUS329J1 Soft seat -50 to +230 -80 to +230 Body material Trim material JIS SCPH2 SCS13A SCS14A SCS16A SCS19A Titanium ASTM CW-12MW (Hastelloy C equivalent) Alloy 20 ASTM A216WCB A351CF8 A351CF8M A351CF3M A351CF3 JIS Titanium alloy -196 to +315 JIS Titanium -196 to +315 JIS ASTM B574 (Hastelloy C-276 equivalent ) -196 to +450 JIS Alloy 20 -196 to +300 JIS Monel -5 to +300 -196 to +300 -196 to +300 -196 to +300 -196 to +300 Table 2 Cv value and travel Plug type/ characteristics / Rated travel (mm) / Rated Cv value 0.01 0.04 0.1 0.16 0.25 0.4 0.63 1.0 1.6 2.5 4.0 6.3 10 14 Contoured type Metal seat Equal percentage (%CF) 14.3 .. .. .. .. .. .. .. .. .. .. Linear (LCF) .. .. .. .. .. .. .. .. .. .. .. .. .. .. Soft seat Equal percentage (%TF) .. .. .. .. .. .. .. .. .. .. Linear (LTF) .. .. .. .. .. .. .. .. .. .. .. Quick-opening type Metal (Stellite) seat (QS) 6.0 .. .. Inherent rangeability 20:1 25:1 20:1 30:1 50:1 Nominal size (inch) 1/2 inch 3/4 inch 1 inch |