Azbil Corporation No. SS2-8113-0210 - 7 - Contoured type metal seat (%CC LCC) : Graphite packing (+230 to +500 °C) Note) 1) ..: Positioner is necessary. 2) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by JIS B 2201-1984 or ANSI B 16.34-1981. 3) The upper figures denote the operating allowable differential pressure. The lower denote allowable differential pressure at full closure. Contoured type metal seat (%CC LCC) : Graphite packing “P6610+M8590” (+500 to +560 °C) Note) 1) ..: Positioner is necessary. 2) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by JIS B 2201-1984 or ANSI B 16.34-1981. 3) The upper figures denote the operating allowable differential pressure. The lower denote allowable differential pressure at full closure. Table 8 Air-to-close Actuator Model No. Supply Pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Positioner Differential pressure {by Cv value} kPa {kgf/cm2} Bellow 0.25 0.4 0.63 1.0 1.6 2.5 4.0 HA2D 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} Table 9 Air-to-open Actuator Model No. Supply Pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Positioner Differential pressure {by Cv value} kPa {kgf/cm2} Bellow 0.25 0.4 0.63 1.0 1.6 2.5 4.0 HA2R 270 {2.8} 80 to 240 {0.8 to 2.4} .. 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} Table 10 Air-to-close Actuator Model No. Supply Pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Positioner Differential pressure {by Cv value} kPa {kgf/cm2} Bellow 0.25 0.4 0.63 1.0 1.6 2.5 4.0 HA2D 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} Table 11 Air-to-open Actuator Model No. Supply Pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Positioner Differential pressure {by Cv value} kPa {kgf/cm2} Bellow 0.25 0.4 0.63 1.0 1.6 2.5 4.0 HA2R 270 {2.8} 80 to 240 {0.8 to 2.4} .. 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 3920* {40.0} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9260 {94.4} 1 3 |