【DO!BOOK・ページリンク】 cv-01 66 / 168 10秒後にBOOKのページに移動します |
|
- 1 - 16th edition No. SS2-8113-0300 CV3000 Series Top-Guided Single Seated Control Valves Model HTS OVERVIEW Model HTS Top-guided Single Seated Control Valves are designed for heavyduty service. The compact valve body, having a S-shape flow passage that features low pressure loss, allows a large flow capacity, rangeability, and high accuracy flow characteristics. The valve plug is highly vibration-resistant as it is held by a top guide section which has a large sliding area. The flow shut-off performance complies with the IEC or JIS Standards. The actuator integrated with simplest mechanisms utilizes a compact yet powerful diaphragm actuator loaded with multiple springs. The model HTS Valves are widely applicable for reliable control, with high shut-off performance, in high or low temperature, high pressure process lines SPECIFICATIONS Body Type: Straight-through, cast globe valve Nominal size: 1., 2, 2., 3, 4, 6, 8 inches Pressure rating: . JIS 10K, 16K, 20K, 30K, 40K . ANSI Class 125, 150, 300, 600 . JPI Class 125, 150, 300, 600 End connection: . Flanged end : . Welded end; SW (1., 2 inches) BW (2. to 8 inches) Material For body/trim material combinations and operating temperature ranges, refer to Table 1. Bonnet . Plain bonnet (-17 to 230°C) . Extension bonnet Type 1 (-45 to -17°C and 230 to 566°C) Connection type Pressure rating Applicable standard FF JIS10K JIS B2210-1984 ANSI Class 125 ANSI B16.5-1981 JPI Class 125 JPI-7S-15-1993 RF JIS10K, 16K, 20K, 30K, 40K JIS B2210-1984 ANSI Class 150, 300, 600 ANSI B16.5-1981 JPI Class150, 300, 600 JPI-7S-15-1993 RJ, LG ANSI Class 150, 300, 600 ANSI B16.5-1981 JPI Class 150, 300, 600 JPI-7S-15-1993 Tongue and groove(groove) Male and female(female) JIS16K, 20K, 30K, 40K JIS B2202-1984 . Extension bonnet Type 2 Integral-cast type (-100 to -45°C) Welded type (-196 to -100°C) . Bellows type (for operating temperature and pressure range, refer to Figure 3.) Note) Take care not to exceed the operating temperature ranges specified for respective materials. Gland type: Bolted gland Packing / Grease . Grease not provided When V shaped PTFE packing or PTFE yarn packing is used . Grease provided When graphite packing is used. Note) PTFE: Polytetrafluoroethylene Gasket Type: Flat type, serrated type Material Carbon steel (S15C), stainless steel (SUS316, SUS316L, SUS329J1), copper, aluminum, titanium, ASTM B574 (Hastelloy C-276 equivalent), or Alloy 20 1 5 Specifications are subject to change without notice. “This product is designed for general industrial use.” |