Azbil Corporation No. SS2-8113-0300 - 15 - Contoured type metal seat (%CF, LCF, %C, LC) : Graphite packing “P6610+P6528” (+230 to +500 °C) Valves with type PSA, HA or VA actuator Note) 1) Column bordered with solid lines (" ”), denote types provided with standard-type actuator. 2)..: Positioner is necessary. 3) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B 16. 34-1981 or JIS B2201-1984. 4) The upper figures denote the operating allowable differential pressure. The lower denote allowable differential pressure at full closure. 5) *1…Applicable to valve sizes of 2. to 4 inches, *2…Applicable to valve size of 6 inches, *3…Applicable to valve size 8 inches. Table 17 Air-to-close Actuator model No. Supply pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Positioner Differential pressure (kPa {kgf/cm2}) Cv value Port size (inches) 2.5 4.0 6.3 1 1. 1. 2 2. 3 4 5 6 8 HA2D 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3380 {34.4} 1950 {19.8} 1230 {12.5} 870 {8.8} 480 9810 {4.8} {100} 9810 {100} 9810 {100} 7830 {79.8} 4770 {48.6} HA3D 3920 {40.0} 3920 {40.0} 3920 {40.0} 3470 {35.3} 2180 {22.2} 1540 {15.7} 860 {8.7} 550 {5.6} 330 9810 {3.3} {100} 8470 {86.3} 6010 {61.2} HA4D 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3860 {39.3} 2720 {27.7} 1530 {15.6} 980 {9.9} 590 {6.0} 370 9810 {3.7} {100} 9810 {100} 9810 {100} 6140 {62.6} VA5D 270 {2.8} 40 to 200 {0.4 to 2.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2910 {29.6} 1830 {18.6} 1290 {13.1} 720 {7.3} 460 {4.6} 280 {2.8} 170 9810 {1.7} {100} 7110 {72.5} 5040 {51.3} Table 18 Air-to-open Actuator model No. Supply pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Positioner Differential pressure (kPa {kgf/cm2}) Cv value Port size (inches) 2.5 4.0 6.3 1 1. 1. 2 2. 3 4 5 6 8 HA2R 270 {2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3410 {34.7} 2080 {21.2} 1470 {14.9} 850 {8.6} 530 {5.4} 370 {3.7} 210 9810 {2.1} {100} 9810 {100} 5900 {60.1} HA3R 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3690 {37.6} 2610 {26.6} 1510 {15.3} 950 {9.6} 670 {6.8} 370 {3.7} 240 {2.4} 140 9810 {1.4} {100} 9810 {100} 9810 {100} 6050 {61.6} HA4R 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2750 {28.0} 1730 {17.6} 1220 {12.4} 680 {6.9} 440 {4.4} 260 {2.6} 160 9810 {1.6} {100} 9810 {100} 9810 {100} 9810 {100} 6720 {68.5} 4770 {48.6} VA5R 3920 {40.0} 3920 {40.0} 3920 {40.0} 3570 {36.4} 2250 {22.9} 1580 {16.1} 890 {9.0} 570 {5.8} 340 {3.4} 210 9810 {2.1} {100} 8720 {88.9} 6180 {63.0} PSA6R 400 {4.0} *1 200 to 340 {2.0 to 3.5} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2370 9810 {24.1} {100} 9810 {100} 9810 {100} 9510 {96.9} 5980 {60.9} 4220 {43.0} 500 {5.0} *2 200 to 390 {2.0 to 4.0} 2730 {24.1} 1520 {15.5} 930 {9.4} 400 {4.0} *3 200 to 340 {2.0 to 3.5} 1520 {15.5} 930 {9.4} 590 {6.0} PSA7R 400 {4.0} *2 200 to 270 {2.0 to 2.8} 4000 {40.7} 2560 {26.1} 1560 {15.9} 400 {4.0} *3 200 to 305 {2.0 to 3.0} 2560 {26.1} 1560 {15.9} 970 {9.8} 1 5 |