Azbil Corporation No. SS2-8113-0300 - 17 - Contoured type metal seat (%CF, LCF, %C, LC) : Graphite packing “P6610+M8590” (+500 to +566 °C) Valves with type PSA, HA or VA actuator Note) 1) Columns bordered with solid lines(" ”), denote types provided with standard-type actuator. 2)..: Positioner is necessary. 3) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B 16. 34-1981 or JIS B2201-1984. 4) The upper figures denote the operating allowable differential pressure. The lower denote allowable differential pressure at full closure. 5) *1…Applicable to valve sizes of 2. to 4 inches, *2…Applicable to valve size of 6 inches, *3…Applicable to valve size 8 inches. Table 20 Air-to-close Actuator model No. Supply pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Positioner Differential pressure (kPa {kgf/cm2}) Cv value Port size (inches) 2.5 4.0 6.3 1 1. 1. 2 2. 3 4 5 6 8 HA2D 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3170 {32.3} 1830 {18.6} 1150 {11.7} 810 {8.2} 450 9810 {4.5} {100} 9810 {100} 9810 {100} 7320 {74.6} 4470 {45.5} HA3D 3920 {40.0} 3920 {40.0} 3920 {40.0} 3240 {33.0} 2040 {20.8} 1440 {14.6} 810 {8.2} 510 {5.2} 310 9810 {3.1} {100} 7930 {80.8} 5620 {57.3} HA4D 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3660 {37.3} 2580 {26.3} 1450 {14.7} 930 {9.4} 560 {5.7} 350 9810 {3.5} {100} 9810 {100} 9810 {100} 5820 {59.3} VA5D 270 {2.8} 40 to 200 {0.4 to 2.0} 9530 {97.1} 5810 {59.2} 3920 {40.0} 2380 {24.2} 1500 {15.2} 1050 {10.7} 590 {6.0} 380 {3.8} 230 {2.3} 140 4120 {1.4} {42.0} Table 21 Air-to-open Actuator model No. Supply pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Positioner Differential pressure (kPa {kgf/cm2}) Cv value Port size (inches) 2.5 4.0 6.3 1 1. 1. 2 2. 3 4 5 6 8 HA2R 270 {2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 2900 {29.5} 1770 {18.0} 1250 {12.7} 720 {7.3} 450 {4.5} 320 {3.2} 180 9260 {1.8} {94.4} 9260 {94.4} 5020 {51.1} HA3R 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3140 {32.0} 2230 {22.7} 1280 {13.0} 810 {8.2} 570 {5.8} 320 {3.2} 200 {2.0} 120 9810 {1.2} {100} 9810 {100} 8920 {90.9} 5150 {52.5} HA4R 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2430 {24.7} 1530 {15.6} 1080 {11.0} 600 {6.1} 390 {3.9} 230 {2.3} 140 9810 {1.4} {100} 9810 {100} 9810 {100} 9810 {100} 5950 {60.6} 4220 {43.0} VA5R 3920 {40.0} 3920 {40.0} 3920 {40.0} 3040 {30.9} 1910 {19.4} 1350 {13.7} 760 {7.7} 480 {4.8} 290 {2.9} 180 9810 {1.8} {100} 7430 {75.7} 5270 {53.7} PSA6R 400 {4.0} *1 200 to 340 {2.0 to 3.5} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2320 9810 {23.6} {100} 9810 {100} 9810 {100} 9290 {94.7} 5850 {59.6} 4130 {42.1} 500 {5.0} *2 200 to 390 {2.0 to 4.0} 2320 {23.6} 1480 {15.0} 900 {9.1} 400 {4.0} *3 200 to 340 {2.0 to 3.5} 1480 {15.0} 900 {9.1} 560 {5.7} PSA7R 400 {4.0} *2 200 to 270 {2.0 to 2.8} 3670 {37.4} 2350 {23.9} 1430 {14.5} 400 {4.0} *3 200 to 305 {2.0 to 3.0} 2350 {23.9} 1430 {14.5} 890 {9.0} 1 5 |