【DO!BOOK・ページリンク】 cv-01 93 / 168 10秒後にBOOKのページに移動します |
|
No. SS2-8113-0310 Azbil Corporation - 6 - Allowable differential pressure Contoured type metal seat (%CC, LCC) : PTFE packing Valves with type PSA1, HA or VA actuator Table 6 Air-to-close Actuator Model No. Supply pressure kPa{Kgf/cm2} Spring range kPa{Kgf/cm2} Positioner Differential pressure kPa {kgf/cm2} 1. 2 2. 3 4 6 Cv =4.0 Cv =6.3 1 Cv =6.3 1 1. 1 1. 1. 1. 1. 2 1. 2 2. 2. 3 4 PSA1D 140 {1.4} 20 to 98 {0.2 to 1.0} .. 1020 {10.4} 550 {5.6} 320 {3.3} 550 {5.6} 320 {3.3} 200 {2.0} 160 {1.6} 20 to 98 {0.2 to 1.0} .. 3920 {40.0} 2710 {28.0} 1570 {16.0} 2740 {28.0} 1570 {16.0} 970 5100 {9.9} {52.0} 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2840 9810 {29.0} {100} 8240 {84.0} 4710 {48.0} 8240 {84.0} 4710 {48.0} HA2D 140 {1.4} 20 to 98 {0.2 to 1.0} .. 1960 {20.0} 981 {10.0} 620 {6.3} 981 {10.0} 620 {6.3} 370 {3.8} 620 {6.3} 370 {3.8} 260 {2.7} 370 {3.8} 260 {2.7} 160 {1.6} 260 {2.7} 160 {1.6} 98 {1.0} 160 {1.6} 20 to 98 {0.2 to 1.0} .. 3920 {40.0} 3920 {40.0} 3100 {31.6} 3920 {40.0} 3100 {31.6} 1890 {19.3} 3100 {31.6} 1890 {19.3} 1340 {13.7} 1890 {19.3} 1340 {13.7} 760 {7.8} 1340 {13.7} 760 {7.8} 500 9810 {5.1} {100} 5300 {54.0} 5300 {54.0} 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2130 {21.7} 3920 {40.0} 2130 {21.7} 1460 9810 {14.9} {100} 9810 {100} 9220 {94.0} 9810 {100} 9220 {94.0} 5590 {57.0} 9220 {94.0} 5590 {57.0} 4020 {41.0} 5590 {57.0} 4020 {41.0} 4020 {41.0} HA3D 140 {1.4} 20 to 98 {0.2 to 1.0} .. 3430 {35.0} 1860 {19.0} 1100 {11.2} 1860 {19.0} 1100 {11.2} 670 {6.8} 1100 {11.2} 670 {6.8} 470 {4.8} 670 {6.8} 470 {4.8} 270 {2.8} 470 {4.8} 270 {2.8} 170 {1.7} 170 {1.7} 120 {1.2} 70 {0.7} 160 {1.6} 20 to 98 {0.2 to 1.0} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3350 {34.2} 3920 {40.0} 3350 {34.2} 2370 {24.2} 3350 {34.2} 2370 {24.2} 1370 {14.0} 2370 {24.2} 1370 {14.0} 860 {8.8} 860 {8.8} 610 {6.2} 340 9810 {3.5} {100} 9510 {97.0} 5490 {56.0} 9510 {97.0} 5490 {56.0} 5490 {56.0} 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2600 {26.5} 2600 {26.5} 1830 {18.7} 1030 9810 {10.5} {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 7060 {72.0} 9810 {100} 7060 {72.0} 4120 {42.0} 7060 {72.0} 4120 {42.0} Table 7 Actuator Model No. Supply pressure kPa{Kgf/cm2} Spring range kPa{Kgf/cm2} Positioner Differential pressure kPa {kgf/cm2} 2. 3 4 6 8 1 1. 1. 1. 1. 2 1. 2 2. 2. 3 4 3 4 5 HA4D 140 {1.4} 20 to 98 {0.2 to 1.0} .. 1860 {19.0} 1080 {11.0} 810 {8.3} 1080 {11.0} 810 {8.3} 470 {4.8} 810 {8.3} 470 {4.8} 290 {3.0} 290 {3.0} 220 {2.2} 120 {1.2} 220 {2.2} 120 {1.2} 69 {0.7} 160 {1.6} 20 to 98 {0.2 to 1.0} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2370 {24.2} 3920 {40.0} 2370 {24.2} 1490 {15.2} 1490 {15.2} 1050 {10.7} 600 {6.1} 1050 {10.7} 600 {6.1} 380 9410 {3.9} {96.0} 5780 {59.0} 5780 {59.0} 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3160 {32.0} 1780 {18.2} 3160 {32.2} 1780 {18.2} 1140 9810 {11.6} {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 7060 {72.0} 9810 {100} 7060 {72.0} 4410 {45.0} 4410 {45.0} VA5D 140 {1.4} 20 to 98 {0.2 to 1.0} .. 2550 {26.0} 1570 {16.0} 1080 {11.0} 1570 {16.0} 1080 {11.0} 650 {6.6} 1080 {11.0} 650 {6.6} 410 {4.2} 410 {4.2} 280 {2.9} 160 {1.6} 280 {2.9} 160 {1.6} 110 {1.1} 160 {1.6} 20 to 98 {0.2 to 1.0} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3240 {33.0} 3920 {40.0} 3240 {33.0} 2040 {20.8} 2040 {20.8} 1440 {14.7} 810 {8.3} 1440 {14.7} 810 {8.3} 810 9810 {8.3} {100} 7840{ 80.0} 5590 {57.0} 7840 {80.0} 5590 {57.0} 5590 {57.0} |