Azbil Corporation No. SS2-8113-0310 - 7 - Valves with type PSA1, HA or VA actuator Note) 1)“ ” shows a model with standard actuator. 2) ..: Positioner is necessary. ..: Can be operated either with or without positioner. 3) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34-1981 or JIS B2201-1984. 4) The upper figures denote the operating allowable differential pressure. The lower denote allowable differential pressure at full closure. Table 8 Air-to-open Actuator Model No. Supply pressure kPa {Kgf/cm2} Spring range kPa {Kgf/cm2} Positioner Differential pressure (Upper side: by nominal size, Lower side: by port size) kPa {kgf/cm2} 1. 2 2. 3 4 6 Cv =4.0 Cv =6.3 1 Cv =6.3 1 1. 1 1. 1. 1. 1. 2 1. 2 2. 2. 3 4 PSA1R 140 {1.4} 20 to 98 {0.2 to 1.0} .. 981 {10.0} 550 {5.6} 320 {3.3} 550 {5.6} 320 {3.3} 200 {2.0} 270 {2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3820 {39.0} 2160 {22.0} 3820 {39.0} 2160 {22.0} 1270 7060 {13.0} {72.0} HA2R 140 {1.4} 20 to 98 {0.2 to 1.0} .. 1960 {20.0} 981 {10.0} 620 {6.3} 981 {10.0} 620 {6.3} 370 {3.8} 620 {6.3} 370 {3.8} 260 {2.7} 370 {3.8} 260 {2.7} 160 {1.6} 260 {2.7} 160 {1.6} 98 {1.0} 270 {2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2650 {27.0} 3920 {40.0} 2650 {27.0} 1380 {14.0} 2650 {27.0} 1380 {14.0} 1090 {11.1} 1380 {14.0} 1090 {11.1} 680 9810 {6.9} {100} 7450 {76.0} 4310 {44.0} 7450 {76.0} 4310 {44.0} 4310 {44.0} HA3R 140 {1.4} 20 to 98 {0.2 to 1.0} .. 3430 {35.0} 1860 {19.0} 1100 {11.2} 1860 {19.0} 1100 {11.2} 670 {6.8} 1100 {11.2} 670 {6.8} 470 {4.8} 670 {6.8} 470 {4.8} 270 {2.8} 470 {4.8} 270 {2.8} 170 {1.7} 170 {1.7} 120 {1.2} 70 {0.7} 270 {2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3330 {34.0} 3920 {40.0} 3330 {34.0} 1920 {19.6} 3330 {34.0} 1920 {19.6} 1210 {12.3} 1210 {12.3} 850 {8.7} 480 9810 {4.9} {100} 9810 {100} 7650 {78.0} 9810 {100} 7650 {78.0} 4610 {47.0} 7650 {78.0} 4610 {47.0} 4610 {47.0} Table 9 Actuator Model No. Supply pressure kPa{Kgf/cm2} Spring range kPa{Kgf/cm2} Positioner Differential pressure (Upper side: by nominal size, Lower side: by port size) kPa {Kgf/cm2} 2. 3 4 6 8 1 1. 1. 1. 1. 2 1. 2 2. 2. 3 4 3 4 5 HA4R 140 {1.4} 20 to 98 {0.2 to 1.0} .. 1860 {19.0} 1080 {11.0} 820 {8.3} 1080 {11.0} 820 {8.3} 470 {4.8} 820 {8.3} 470 {4.8} 290 {3.0} 290 {3.0} 220 {2.2} 120 {1.2} 220 {2.2} 120 {1.2} 70 {0.7} 270 {2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3090 {31.5} 3920 {40.0} 3090 {31.5} 2090 {21.3} 2090 {21.3} 1470 {15.0} 830 {8.5} 1470 {15.0} 830 {8.5} 530 9810 {5.4} {100} 8040 {82.0} 5690 {58.0} 8040 {82.0} 5690 {58.0} 5690 {58.0} VA5R 140{1 .4} 20 to 98 {0.2 to 1.0} .. 2550 {26.0} 1570 {16.0} 1080 {11.0} 1570 {16.0} 1080 {11.0} 650 {6.6} 1080 {11.0} 650 {6.6} 410 {4.2} 410 {4.2} 280 {2.9} 170 {1.6} 280 {2.9} 170 {1.7} 110 {1.1} 270 {2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2860 {29.2} 2860 {29.2} 2020 {20.6} 1140 {11.6} 2020 {20.6} 1140 {11.6} 720 9810 {7.4} {100} 9810 {100} 7840 {80.0} 9810 {100} 7840 {80.0} 4510 {46.0} 7840 {80.0} 4510 {46.0} PSA6R 400 {4.0} 200 to 340 {2.0 to 3.5} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 5980 {61.0} 500 {5.0} 200 to 390 {2.0 to 4.0} .. 3920 {40.0} 3920 {40.0} 2370 5980 {24.2} {61.0} 4220 {43.0} 1 6 |