【DO!BOOK・ページリンク】
cv-01   95 / 168

BOOKをみる

10秒後にBOOKのページに移動します


No. SS2-8113-0310 Azbil Corporation - 8 - Valves with type VP actuator Note) 1) When a backup system for pressure drop at the air source is used, select the allowable differential pressure from whichever is lower constant supplied air pressure or backup system set pressure (trip pressure). 2) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34-1981 or JIS B2201-1984. 3) The upper figures denote the operating allowable differential pressure. The lower denote allowable differential pressure at full closure. Table 10 Air-to-close and Air-to-open Actuator Model No. Supply Pressure kPa{Kgf/cm2} Differential pressure (Upper side: by nominal size, Lower side: by port size) kPa {Kgf/cm2} 2. 3 4 6 8 1 1. 1. 1. 1. 2 1. 2 2. 2. 3 4 3 4 5 VP5 290 {3.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3610 {36.8} 2030 {20.7} 3610 {36.8} 2030 {20.7} 1290 9810 {13.2} {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 8430 {86.0} 9810 {100} 8430 {86.0} 5100 {52.0} 5100 {52.0} 390 {4.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 27.8 {2730} 3920 {40.0} 2730 {27.8} 1740 9810 {17.8} {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 6860 {70.0} 6860 {70.0} 49.0 {4800} 4800 {49.0} 490 {5.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3420 {34.9} 3920 {40.0} 3420 {34.9} 2200 9810 {22.4} {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 8630 {88.0} 8630 {88.0} 6080 {62.0} 6080 {62.0} VP6 290 {3.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3620 {36.9} 3920 {40.0} 3620 {36.9} 2310 9810 {23.6} {100} 9810 {100} 9120 {93.0} 9120 {93.0} 6370 {65.0} 6370 {65.0} 390 {4.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3120 9810 {31.8} {100} 9810 {100} 9810 {100} 9810 {100} 8630 {88.0} 49.0 {4800} 8630 {88.0} 4800 {49.0} 490 {5.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 9810 {40.0} {100} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 6080 {62.0} 9810 {100} 6080 {62.0} VP7 290 {3.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3480 9810 {35.5} {100} 9710 {99.0} 5490 {56.0} 9710 {99.0} 5490 {56.0} 390 {4.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 9810 {100} 9810 {100} 7160 {73.0} 9810 {100} 7160 {73.0} 4610 {47.0} 490 {5.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 9810 {100} 9810 {100} 9020 {92.0} 9810 {100} 9020 {92.0} 5880 {60.0}