【DO!BOOK・ページリンク】 cv-02 130 / 132 10秒後にBOOKのページに移動します |
|
Azbil Corporation No. SS2-D1M100-0100 Table 2. Face-to-face dimensions [Unit: mm] Nominal size (inches) F/F Class 150RF (PN 20) Class 300RF (PN 50) Class 600RF (PN 100) 1-1/2 222 235 251 2 254 267 286 2-1/2 276 292 311 3 298 318 337 4 352 368 394 6 451 473 508 8 543 568 610 10 673 708 752 12 737 775 819 14 889 927 972 16 1016 1057 1108 18 1143 20 1267 22 1367 24 1556 28 1648 30 1724 32 1740 36 1956 Table 3. External dimension [Unit: mm] Nominal size (inches) Actuator Model No. Pressure rating H Without φD hand wheel With side hand wheel 1-1/2 M-11 ClCaslsa s1s5 600/3000 551455 881405 290 M-22 ClCaslsa s1s5 600/3000 554700 886900 380 6 M-33 ClCaslsa s1s5 600/3000 897150 11331505 448 8 M-34 ClCaslsa s1s5 600/3000 1905100 11347605 600 10 M-44 ClCaslsa s1s5 600/3000 11221600 11678300 600 12 M-44 ClCaslsa s1s5 600/3000 11349300 11882605 600 14 M-44 Class 150/300 * * Class 600 * * 600 16 M-44 ClCaslsa s1s5 600/3000 11458200 22001600 600 18 PD-200-178 Class 150/300/600 1140 1540 262 PD-250-178 1160 1580 325 20 PD-200-178 Class 150/300/600 1480 1740 262 PD-250-178 1522 2140 325 22 PD-250-198 Class 150/300/600 1720 2320 325 PD-300-198 1790 2490 380 24 PD-250-198 Class 150/300/600 1935 2685 325 PD-300-198 1980 2730 380 28 PD-300-308 Class 150/300/600 2220 3020 380 PD-350-308 2280 3180 418 30 PD-300-308 Class 150/300/600 2450 3250 380 PD-350-308 2570 3250 418 32 PD-300-308 Class 150/300/600 2608 3350 380 PD-350-308 2690 3450 418 36 PD-300-308 Class 150/300/600 2800 3550 380 PD-350-308 2840 3620 418 *Contact your Azbil sales office. 5 2 14 |