【DO!BOOK・ページリンク】 cv-02 20 / 132 10秒後にBOOKのページに移動します |
|
Azbil Corporation No. SS2-ACP110-0100 - 7 - Allowable differential pressure (temperature range: 230 to 400°C) Metal seat (%V, LV) : Graphite packing “P6610CH+P6528” Note) 1. “ “ shows a model with standard actuator. 2. ..: Positioner is necessary. ..: Can be operated either with or without positioner. 3. Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34- 1981 or JIS B2201-1984. 4. The upper figures denote the operating allowable differential pressure. The lower denote allowable differential pressure at full closure. DIMENSIONS Note) * : Face-to-face dimensions conform to following standards. - IEC 60534-3-1 : 2001 - IEC 60534-3-3 : 1998 (2. inches or over) - JIS B 2005-3-1 : 2005 - JIS B 2005-3-3 : 2005 (2. inches or over) Table 10 Air-to-close Actuator model No. Supply pressure kPa{kgf/cm2} Spring range kPa{kgf/cm2} Positioner Differential pressure (by nominal size (inches)) kPa {kgf/cm2} 1. 2 2. 3 4 5 6 8 HA3D 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 9810 {100.0} 9810 {100.0} 9630 {98.2} 9240 {94.2} 7600 {77.4} 7600 {77.4} 4290 {43.7} HA4D 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 9810 {100.0} 9810 {100.0} 9050 {92.2} 7040 {71.7} Table 11 Air-to-open Actuator model No. Supply pressure kPa{kgf/cm2} Spring range kPa{kgf/cm2} Positioner Differential pressure (by nominal size (inches)) kPa {kgf/cm2} 1. 2 2. 3 4 5 6 8 HA3R 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3420 {34.8} 3030 {30.8} 3030 {30.8} 3030 {30.8} 1730 5760 {17.6} {58.7} 4470 {45.5} HA4R 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3760 {38.3} 2930 6670 {29.8} {68.0} 6670 {68.0} Table 12 Face-to-face dimensions [Unit: mm] Nominal size (inches) A JIS 10KFF, RF ANSI 125FF ANSI 150RF JPI 150RF * JIS 16KRF JIS 20KRF JIS 30KRF ANSI 300RF JPI 300RF * JIS 40KRF ANSI 600RF JPI 600RF * JIS 16K Tongue and groove Male & female JIS 20K Tongue and groove Male & female JIS 30K Tongue and groove Male & female JIS 40K Tongue and groove Male & female 1. 222 231 235 251 235 236 248 251 2 254 263 267 286 265 267 276 286 2. 276 288 292 311 290 292 303 311 3 298 313 317 337 310 317 326 337 4 352 364 368 394 360 368 379 394 5 403 425 425 457 6 451 465 473 508 475 473 486 508 8 543 560 568 610 570 568 580 610 Nominal size (inches) A ANSI 150RJ JPI 150RJ ANSI 300RJ JPI 300RJ ANSI 600RJ JPI 600RJ ANSI 300LG JPI 300LG ANSI 600LG JPI 600LG ANSI 150 JPI 150 SW, BW * ANSI 300 JPI 300 SW, BW * ANSI 600 JPI 600 SW, BW * 1. 235 248 251 244 248 251 251 251 2 267 283 289 276 283 286 286 286 2. 289 308 314 302 308 311 311 311 3 311 333 340 327 333 337 337 337 4 365 384 397 378 391 394 394 394 5 416 441 460 441 460 425 425 457 6 464 489 511 483 505 473 508 508 8 556 584 613 578 606 568 610 610 2 2 |