【DO!BOOK・ページリンク】 cv-02 21 / 132 10秒後にBOOKのページに移動します |
|
No. SS2-ACP110-0100 Azbil Corporation - 8 - DIMENSIONS Note) 1)"H" dimension are applicable when a hand wheel is not provided. When top-mounted hand wheel are used, add the hand wheel dimensions designated in specification sheet (No.SS2-8213-0500). Note) 2)"H" dimensions of Extension bonnet Type 1 are as follows: The left side for JIS 10K and ANSI 150, and the right side for JIS 16K and ANSI 300 or over. Table 13 External dimensions [Unit: mm] Nominal size (inches) Actuator model No. H B .. B E Figure 4 Face-to-face and other dimensions Plain bonnet Extension bonnet Type 1 Extension bonnet Type 2 Integral cast type Welded type 1 . HA2D, R 500 665 780 1020 281 267 70 HA3D, R 590 765 875 1140 363 350 2 HA2D, R 500 670 785 1025 281 267 80 HA3D, R 595 765 875 1140 363 350 2 . HA2D, R 575 745/755 880 1130 281 267 90 HA3D, R 630 800/810 930 1180 363 350 3 HA2D, R 580 755/765 900 1135 281 267 100 HA3D, R 635 810/820 955 1190 363 350 4 HA2D, R 610 810/820 915 1150 281 267 HA3D, R 660 860/870 1020 1205 363 350 115 HA4D, R 890 1100/1110 1255 1520 520 470 5 HA3D, R 775 925 1265 1365 363 350 141 HA4D, R 945 1095 1435 1535 520 470 6 HA3D, R 785 1020/1045 1250 1385 363 350 170 HA4D, R 955 1190/1215 1425 1570 520 470 8 HA4D, R 1090 1350 1580 1710 470 220 Table 14 Weight [Unit: kg] Nominal size (inches) Actuator model no. Weight Flange type JIS 10K, ANSI/JPI150 Flange type JIS 16K, 20K, 30K, ANSI/JPI 300 Flange type JIS 40K, ANSI/JPI 600 Welded type JIS 10K, 16K, 20K, 30K, ANSI/JPI 150, 300, 600 Plain bonnet Extension Type 1 Bellows type Extension Type 2 Plain bonnet Extension Type 1 Bellows type Extension Type 2 Plain bonnet Extension Type 1 Bellows type Extension Type 2 Plain bonnet Extension Type 1 Bellows type Extension Type 2 Integral cast type Welded type Integral cast type Welded type Integral cast type Welded type Integral cast type Welded type 1 . HA2R,R 31 34 37 39 36 39 42 44 44 47 50 52 36 39 42 44 HA3D,R 43 46 49 51 48 51 54 56 56 59 62 64 64 51 54 56 2 HA2D,R 37 40 43 45 42 45 48 50 47 50 53 55 42 45 48 50 HA3D,R 49 52 55 57 54 57 60 62 59 62 65 67 54 57 60 62 2 . HA2D,R 43 47 51 53 48 52 56 58 65 69 73 75 48 52 56 58 HA3D,R 55 59 63 65 60 64 68 70 77 81 85 87 60 64 68 70 3 HA2D,R 53 59 65 68 63 69 75 78 85 91 97 100 63 69 75 78 HA3D,R 65 71 77 80 75 81 87 90 97 103 109 112 75 81 87 90 4 HA2D,R 63 73 78 81 78 88 93 96 113 123 128 131 75 85 90 93 HA3D,R 75 85 90 93 90 100 105 108 125 135 140 143 87 97 102 105 HA4D,R 106 116 121 124 121 131 136 139 156 166 171 174 118 128 133 136 5 HA3D,R 132 140 154 157 142 150 164 167 187 195 209 212 135 143 157 160 HA4D,R 168 176 190 193 178 186 200 203 223 231 245 258 168 179 190 193 6 HA3D,R 157 172 179 182 187 202 209 212 237 252 259 262 177 192 199 202 HA4D,R 188 203 210 213 218 233 240 243 268 283 290 293 208 223 230 233 8 HA4D,R 268 288 298 303 318 338 348 353 438 458 468 473 308 328 338 343 B H E A φB |