No. SS2-8113-1100 Azbil Corporation - 10 - Soft seat (%TF, LTF, %T, LT) Note) 1. “ ” shows a model with standard actuator. 2. ..: Positioner is necessary, ..: Can be operated either with or without positioner. 3. Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B 16. 34-1981 or JIS B2201-1984. 4. Seat leakages of items marked with asterisk(*) are less than 0.01% (Class IV). Those for items without asterisk marks(*) are less than 0.00001% (Class VI). Table 10 Air-to-close Actuator model No. Supply pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Positioner Differential pressure (by nominal size (inches)) kPa {kgf/cm2} 1. 2 2. 3 4 6 8 PSA1D 140{1.4} 20 to 98 {0.2 to 1.0} .. 350* {3.6} 270* {2.8} --- --- --- --- --- 160{1.6} 20 to 98 {0.2 to 1.0} .. 1670 {17.0} 1270 {13.0} --- --- --- --- --- 390 {4.0} 80 to 240 {0.8 to 2.4} .. 2940 {30.0} 2940 {30.0} --- --- --- --- --- HA2D 140 {1.4} 20 to 98 {0.2 to 1.0} .. 680* {6.9} 530* {5.4} 450* {4.6} 370* {3.8} 280* {2.9} --- --- 160 {1.6} 20 to 98 {0.2 to 1.0} .. 2940 {30.0} 2610 {26.6} 2260 {23.0} 1880 {19.2} 1430 {14.6} --- --- 390 {4.0} 80 to 240 {0.8 to 2.4} .. 2940 {30.0} 2940 {30.0} 2940 {30.0} 2940 {30.0} 2940 {30.0} --- --- HA3D 140 {1.4} 20 to 98 {0.2 to 1.0} .. 1210* {12.3} 940* {9.6} 800* {8.2} 670* {6.8} 510 {5.2} 350* {3.6} --- 160 {1.6} 20 to 98 {0.2 to 1.0} .. 2940 {30.0} 2940 {30.0} 2940 {30.0} 2940 {30.0} 2540 {25.9} 1790 {18.3} --- 390 {4.0} 80 to 240 {0.8 to 2.4} .. 2940 {30.0} 2940 {30.0} 2940 {30.0} 2940 {30.0} 2940 {30.0} 2940 {30.0} --- HA4D 140 {1.4} 20 to 98 {0.2 to 1.0} .. --- --- 1380* {14.1} 1150* {11.7} 880* {9.0} 620* {6.3} 510 {5.2} 160 {1.6} 20 to 98 {0.2 to 1.0} .. --- --- 2940 {30.0} 2940 {30.0} 2940 {30.0} 2940 {30.0} 2540 {25.9} 390 {4.0} 80 to 240 {0.8 to 2.4} .. --- --- 2940 {30.0} 2940 {30.0} 2940 {30.0} 2940 {30.0} 2940 {30.0} Table 11 Air-to-open Actuator model No. Supply pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Positioner Differential pressure (by nominal size (inches)) kPa {kgf/cm2} 1. 2 2. 3 4 6 8 PSA1R 140 {1.4} 20 to 98 {0.2 to 1.0} .. 350* {3.6} 270* {2.8} --- --- --- --- --- 270 {2.8} 80 to 240 {0.8 to 2.4} .. 2450 {25.0} 1860 {19.0} --- --- --- --- --- HA2R 140 {1.4} 20 to 98 {0.2 to 1.0} .. 680* {6.9} 530* {5.4} 450* {4.6} 370* {3.8} 280* {2.9} --- --- 270 {2.8} 80 to 240 {0.8 to 2.4} .. 2940 {30.0} 2940 {30.0} 2940 {30.0} 2640 {26.9} 2010 {20.5} --- --- HA3R 140 {1.4} 20 to 98 {0.2 to 1.0} .. 1210* {12.3} 940* {9.6} 800* {8.2} 670* {6.8} 510* {5.2} 350* {3.6} --- 270 {2.8} 80 to 240 {0.8 to 2.4} .. 2940 {30.0} 2940 {30.0} 2940 {30.0} 2940 {30.0} 2940 {30.0} 2520 {25.7} --- HA4R 140 {1.4} 20 to 98 {0.2 to 1.0} .. --- --- 1380* {14.1} 1150* {11.7} 880* {9.0} 620* {6.3} 510* {5.2} 270 {2.8} 80 to 240 {0.8 to 2.4} .. --- --- 2940 {30.0} 2940 {30.0} 2940 {30.0} 2940 {30.0} 2940 {30.0} |