No. SS2-8113-1100 Azbil Corporation - 12 - Metal seat (%VF, LVF, %V, LV): Graphite packing "P6610CH+M8590" (+500 to +566 °C) Valves with type PSA, HA or VA actuator Note) 1) “ ” shows a model with standard actuator. 2)..: Positioner is necessary. 3) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B 16. 34-1981 or JIS B2201-1984. 4) The upper figures denote the operating allowable differential pressure. The lower denote allowable differential pressure at full closure. Note) 1) “ ” shows a model with standard actuator. 2)..: Positioner is necessary. 3) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B 16. 34-1981 or JIS B2201-1984. 4) The upper figures denote the operating allowable differential pressure. The lower denote allowable differential pressure at full closure. 5) *1.. Applicable to valve sizes of 21/2 to 4 inches, *2 .. Applicable to valve size of 6 inches, *3 .. Applicable to valve size of 8 inches Table 14 Air-to-close Actuator model No. Supply pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Positioner Differential pressure (by nominal size (inches)) kPa {kgf/cm2} 1. 2 2. 3 4 6 8 HA2D 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 9810 {100} 8940 {91.1} 7630 {77.8} 6350 {64.7} 4850 {49.4} HA3D 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 8600 {87.6} 6080 {61.9} HA4D 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 9810 {100} 9810 {100} 9810 {100} 9810 {100} 8880 {90.5} Table 15 Air-to-open Actuator model No. Supply pressure kPa {kgf/cm2} Spring range kPa {kgf/cm2} Positioner Differential pressure (by nominal size (inches)) kPa {kgf/cm2} 1. 2 2. 3 4 6 8 HA2R 270{2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3540 {36.0} 3020 {30.7} 2520 {25.6} 1920 4530 {19.5} {46.1} HA3R 270{2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3410 {34.7} 2410 8050 {24.5} {82.0} 6290 {64.1} 5360 {54.6} 4470 {45.5} HA4R 270{2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3710 9810 {37.8} {100} 8470 {86.3} 6460 {65.8} 4560 {46.4} VA5R 270{2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 8060 {82.1} 5690 {58.0} 4640 {47.3} PSA6R 400{4.0} *1 200 to 340 {2.0 to 3.5} .. 3920 {40.0} 9810 {100} 500{5.0} *2 200 to 390 {2.0 to 4.0} 3920 {40.0} 9810 {100} 400{4.0} *3 200 to 340 {2.0 to 3.5} 3920 {40.0} 9810 {100} |