No. SS2-8113-1200 Azbil Corporation - 2 - Trim Valve plug Pressure balanced type Cage (split cage) Equal percentage(%V) Linear cage (LV) Material For body/trim material combinations and operating temperature ranges, refer to Table 1. Actuator Type Single acting diaphragm actuator (Type HA or VA5) Spring Type piston actuator (Type PSA6) Double acting piston actuator (Type DAP) Action Direct or reverse action Diaphragm Type HA : Cloth embedded ethylene propylene rubber Type VA : Cloth embedded chloroprene rubber Spring range Type HA, Type VA5 40 to 200 kPa {0.4 to 2.0 kgf/cm2} 80 to 240 kPa {0.8 to 2.4 kgf/cm2} Type PSA6 200 to 340 kPa {2.0 to 3.5 kgf/cm2} 200 to 390 kPa {2.0 to 4.0 kgf/cm2} Supply pressure Diaphragm actuator Type HA : 270 to 390 kPa {2.8 to 4.0 kgf/cm2} Type VA5 : 270 kPa {2.8 kgf/cm2} Spring type piston actuator Type PSA6:400 to 490 kPa {4.0 to 5.0 kgf/cm2} Piston actuator Type DAP : 290 to 490 kPa {3.0 to 5.0 kgf/cm2} Note) Allowable differential pressure varies depending on spring range and air supply pressure. Air connection: Rc1/4 or 1/4NPT internal thread Note) With type VA or DAP, Rc1/4 or 1/4NPT adapter is provided on Rc. internal thread (also providing Rc3/8 adapter is possible). Ambient temperature -30 to 70°C Valve action Air-to-close (Direct action actuator is combined.) Air-to-open (Reverse action actuator is combined.) Optional accessories Positioner*, pressure regulator with filter, hand wheel*, limit switch, solenoid valve, motion transmitter, booster relay, lock-up valve, and others. Note) For the optional items, refer to the specification sheets and installation drawings of respective accessaries. Additional specification (by special order) . Special inspection . Flow characteristics inspection, material inspection (Material certificate ), non-destructive inspection, steam inspection. . With drain plug . Double gland . Oil/Water free treatment . Copper free treatment . Yoke material SCPH2 . Stainless steel (SUS304) atmosphere-exposed nuts and bolts . Special air piping and joint . Sand-/dust-preventive measures . Saline damage countermeasures . Cold-area use specifications . Tropical-area use specification Performance Rated Cv value Refer to Table 2. Flow characteristics Refer to Figure 1. Inherent rangeability 50 : 1 Optional; 75:1(full port only) Allowable differential pressure Refer to Table 11 to Table 10 Leakage specification IEC 60534-4:2006 or JIS B 2005-4:2008 Metal seat Standard..........Class III: Leakage less than 0.1% of maximum valve capacity. Hysteresis error With positioner Within 1% F.S. (Within 2% F.S.) Linearity With positioner: Within ±1% F.S. (Within ±2% F.S.) Note) Parenthesized figures are applicable to type PSA6. Dimensions Refer to Figure 3, Table 14 and Table 15. Weight Refer to Table 16. Actuator orientation Refer to Figure 4. Finish Blue (Munsell 10B5/10) or silver, or other specified colors. Actuator Positioner Hand wheel P/P I/P Top Side HA3, 4 HTP AVP/HEP THM SHM VA5 HTP AVP/HEP THM SHM PSA6 HTP/VPP AVP/HEP - SHM DAP560 DAP1000 DAP1500 VPP AVP/HEP - SHM (hydraulic) |