【DO!BOOK・ページリンク】 cv-02 88 / 132 10秒後にBOOKのページに移動します |
|
Azbil Corporation No. SS2-ACN110-0100 - 3 - Finish Blue (Munsell 10B5/10) or silver, or their specified colors. Cv value and travel Table 1 Body / trim material combinations and operating temperature ranges (°C) Body material Trim material JIS FC200 SCPH2 SCPH21 SCS61 SCPL1 SCS 13A SCS14A ASTM A126Gr.B A216WCB A217WC6 A217C5 A352LCB A351CF8 A351CF8M ASTM A351CF8M 0 to 200 -5 to 230 -5 to 230 -5 to 230 -45 to 230 -196 to 230 -196 to 230 ASTM A351CF8M /SUS316 Stellite - -5 to 400 -5 to 400 -5 to 400 -45 to 350 -196 to 400 -196 to 400 Table 2 Cv value and travel (temperature range: -196 to 230°C) Nominal size (inches) 1 . 2 2 . 3 4 5 6 8 Port size (inches) 1 1.1.1.1. 2 1. 2 2. 2 2. 3 2. 3 4 3 4 5 4 5 6 5 6 8 Rated Cv value (LV) 11 17 24 17 24 44 24 44 68 44 68 99 68 99 120 54 96 150 120 175 330 175 330 580 Rated travel (mm) 25 38 50 75 Table 3 Cv value and travel (temperature range: +230 to +400°C) Nominal size (inches) 1 . 2 2 . 3 4 5 6 8 Port size (inches) 1 1.1. 1 1. 2 1. 2 2. 2 2. 3 2. 3 4 3 4 5 4 5 6 5 6 8 Rated Cv value (LV) - - 24 - - 44 - - 68 - - 99 68 99120 54 96 150 120 175 330 175 330 580 Rated travel (mm) 25 38 50 75 Figure 1 Flow characteristics Figure 2 Temperature / normal differential pressure ranges requiring Stellite Note) For cavitation / flashing service or oil prohibitive service, Stellite is recommended regardless of temperature and differential pressure. Cv value (%) Travel (%) 100 80 60 40 20 0 0 20 40 60 80 100 1470 {15} kPa {kgf/cm2} 981 {10} 490 {5} 0 -196 0 +100 +200 +300 Stellite Normal differential pressure Fluid temperature ( C) 2 9 |