【DO!BOOK・ページリンク】 cv-02 91 / 132 10秒後にBOOKのページに移動します |
|
No. SS2-ACN110-0100 Azbil Corporation - 6 - Allowable differential pressure (temperature range: -196 to 230°C) Metal seat (LV) : PTFE packing Note)1) “ ” shows a model with standard actuator. 2) ..: Positioner is necessary. ..: Can be operated either with or without positioner. 3) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34-1981 or JIS B2201-1984. 4) The upper figures denote the allowable differential pressure. The lower denote allowable differential pressure at full closure. 5) Combination of supply pressure 140 kPa and without positioner is able to be selected only for ON-OFF application. Table 8 Air-to-close Actuator model No. Supply pressure kPa{kgf/cm2} Spring range kPa{kgf/cm2} Positioner Differential pressure (by nominal size (inches)) kPa {kgf/cm2} 1. 2 2. 3 4 5 6 8 HA2D 140 {1.4} 20 to 98 {0.2 to 1.0} .. 3920 {40.0} 2300 {23.5} 1310 {13.4} 540 {5.5} 3950 {40.3} 2300 {23.5} 1310 {13.4} 540 {5.5} 160 {1.6} 20 to 98 {0.2 to 1.0} .. 3920 {40.0} 3920 {40.0} 3760 {38.3} 2820 {28.8} 1240 {12.6} 7900 {80.6} 5380 {54.9} 3920 {40.0} 2820 {28.8} 1240 {12.6} 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 9810 {100.0} 9810 {100.0} 9810 {100.0} 9810 {100.0} HA3D 140 {1.4} 20 to 98 {0.2 to 1.0} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 2890 {29.5} 1470 {15.0} 8760 {89.3} 6810 {69.4} 4640 {47.3} 2890 {29.5} 1470 {15.0} 160 {1.6} 20 to 98 {0.2 to 1.0} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2050 {20.9} 1560 {15.9} 9810 {100.0} 9810 {100.0} 9280 {94.6} 6750 {68.8} 4400 {44.9} 2050 {20.9} 2070 {21.1} 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 9810 {100.0} 9810 {100.0} 9810 {100.0} HA4D 140 {1.4} 20 to 98 {0.2 to 1.0} .. 3920 {40.0} 2660 {27.1} 1900 {19.4} 1020 {10.4} 5070 {51.7} 2660 {27.1} 2680 {27.3} 1450 {14.8} 160 {1.6} 20 to 98 {0.2 to 1.0} .. 3920 {40.0} 3920 {40.0} 3450 {35.2} 2280 {23.2} 9810 {100.0} 6210 {63.3} 6250 {63.7} 4360 {44.5} 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 9810 {100.0} Table 9 Air-to-open Actuator model No. Supply pressure kPa{kgf/cm2} Spring range kPa{kgf/cm2} Positioner Differential pressure (by nominal size (inches)) kPa {kgf/cm2} 1. 2 2. 3 4 5 6 8 HA2R 140{1.4} 20 to 98 {0.2 to 1.0} .. 270{2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2840 {29.0} 9810 {100.0} 8450 {86.2} 6540 {66.7} 4890 {49.9} 2890 {29.5} HA3R 140{1.4} 20 to 98 {0.2 to 1.0} .. 1750 {17.8} 1360 {13.9} 1750 {17.8} 1360 {13.9} 270{2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 2460 {25.1} 9810 {100.0} 9810 {100.0} 9810 {100.0} 7340 {74.8} 4110 {41.9} 4140 {42.2} HA4R 140{1.4} 20 to 98 {0.2 to 1.0} .. 270{2.8} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3540 {36.1} 9810 {100.0} 9750 {99.4} 9810 {100.0} 7270 {74.1} |