Azbil Corporation No. SS2-ACN110-0100 - 7 - Allowable differential pressure (temperature range: 230 to 400°C) Note) 1) “ “ shows standard combination of valve body and trim materials 2) ..: Positioner is necessary. 3) Take care not to cause the maximum allowable differential pressure to exceed the maximum operating pressure designated by ANSI B16. 34- 1981 or JIS B2201-1984. 4) The upper figures denote the allowable differential pressure. The lower denote allowable differential pressure at full closure. DIMENSIONS Note) * : Face-to-face dimensions conform to following standards. - IEC 60534-3-1 : 2001 - IEC 60534-3-3 : 1998 (2. inches or over) - JIS B 2005-3-1 : 2005 - JIS B 2005-3-3 : 2005 (2. inches or over) Table 10 Air-to-close Actuator model No. Supply pressure kPa{kgf/cm2} Spring range kPa{kgf/cm2} Positioner Differential pressure (by nominal size (inches)) kPa {kgf/cm2} 1. 2 2. 3 4 5 6 8 HA3D 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 9810 {100.0} 9810 {100.0} 9630 {98.1} 9240 {94.5} 7600 {77.4} 7600 {77.4} 4290 {43.7} HA4D 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3920 {40.0} 3920 {40.0} 9810 {100.0} 9810 {100.0} 9050 {92.2} 7040 {71.7} Table 11 Air-to-open Actuator model No. Supply pressure kPa{kgf/cm2} Spring range kPa{kgf/cm2} Positioner Differential pressure (by nominal size (inches)) kPa {kgf/cm2} 1. 2 2. 3 4 5 6 8 HA3R 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3420 {34.8} 3030 {30.8} 3030 {30.8} 3030 {30.8} 1730 5760 {17.6} {58.7} 4470 {45.5} HA4R 390 {4.0} 80 to 240 {0.8 to 2.4} .. 3920 {40.0} 3920 {40.0} 3760 {38.3} 2930 6670 {29.8} {68.0} 6670 {68.0} Table 12 Face-to-face dimensions [Unit: mm] Nominal size (inches) A JIS 10K FF, RF ANSI 150RF JPI 150RF * JIS 16KRF JIS 20K RF JIS 30K RF ANSI 300 RF JPI 300 RF * JIS 40K RF ANSI 600 RF JPI 600 RF * JIS 16K Tongue and groove Male and female JIS 20K Tongue and groove Male and female JIS 30K Tongue and groove Male and female JIS 40K Tongue and groove Male and female 1. 222 231 235 251 235 236 248 251 2 254 263 267 286 265 267 276 286 2. 276 288 292 311 290 292 303 311 3 298 313 317 337 310 317 326 337 4 352 364 368 394 360 368 379 394 5 403 425 425 457 6 451 465 473 508 475 473 486 508 8 543 560 568 610 570 568 580 610 Nominal size (inches) A ANSI 150RJ JPI 150RJ ANSI 300RJ JPI 300RJ ANSI 600RJ JPI 600RJ ANSI 300LG JPI 300LG ANSI 600LG JPI 600LG ANSI 150 JPI 150SW, BW * ANSI 300 JPI 300SW, BW * ANSI 600 JPI 600SW, BW * 1. 235 248 251 244 248 251 251 251 2 267 283 289 276 283 286 286 286 2. 289 308 314 302 308 311 311 311 3 311 333 340 327 333 337 337 337 4 365 384 397 378 391 394 394 394 5 416 441 460 441 460 425 425 457 6 464 489 511 483 505 473 508 508 8 556 584 613 578 606 568 610 610 2 9 |