【DO!BOOK・ページリンク】 cv-03 26 / 32 10秒後にBOOKのページに移動します |
|
- 1 - 4th edition No. SS2-8113-2610 Ceramic Trim Angle Control Valves Model HAF OVERVIEW Model HAF ceramic trim angle control valves provide the valve plug and sheet ring employing high performance ceramic with excellent errosion-proof capability, which most likely apts to accept damage. The HAF are best-suited for FCC of petroleum refinery, control of slurries such as paper and pulp control process. The actuator employs compact, high output multi-spring type diaphragm motor. SPECIFICATIONS Body Type Cast angle valve Nominal size 1, 1., 2, 2., 3, 4 inches Pressure rating . JIS 10K, 16K, 20K, 30K, 40K . ANSI Class 150, 300, 600 . JPI Class 150, 300, 600 End connection Flanged end: Material For body/trim material combinations and operating temperature ranges, refer to Table 1. Connection type Pressure rating Applicable standard FF JIS10K JIS B2212-1972 ANSI Class 125 ANSI B16.5-1968 JPI Class 125 JPI-7S-15-1993 RF JIS10K JIS B2212-1972 JIS16K JIS B2213-1967 JIS20K JIS B2214-1967 JIS30K JIS B2215-1967 JIS40K JIS B2216-1967 ANSI Class 150, 300, 600 ANSI B16.5-1968 JPI Class 150, 300, 600 JPI-7S-15-1993 RJ ANSI Class 150, 300, 600 ANSI B16.5-1968 JPI Class 150, 300, 600 JPI-7S-15-1993 Bonnet . Plain bonnet (0 to 200 °C) . Extension bonnet (-50 to 0°C and 200 to 425°C) Gland type Bolted gland Packing/Grease . Grease not provided When V shaped PTFE packing or PTFE yarn packing is used. . Grease provided When graphite packing is used. Note) PTFE: Polytetrafluoroethylene Gasket Type Serrated type Material Stainless steel SUS316 3 4 Specifications are subject to change without notice. “This product is designed for general industrial use.” |