Azbil Corporation No. SS2-8114-0300 - 3 - Leakage specification Contoured type plug IEC 60534-4:2006 or JIS B 2005-4:2008 Standard.....Class IV: Leakage less than 0.01% of maximum valve capacity. Option........Leakage less than 0.001% of maximum valve capacity. Standard....Class VI: Leakage less than 0.00001% of maximum valve capacity. Option.......Leakage less than 0.001% of maximum valve capacity. Accuracy: Within ±2% F.S. Dead band: Within 1% F.S. Hysteresis error: Within 2% F.S. Linearity: Within ±2% F.S. Operating time (fully open .. fully closed, load reference value) Valve size 1., 2 inches; 21 sec. 2. ~ 4 inches; 32 sec. 6 inches; 31 sec. 8 inches; 47 sec. Dimensions Refer to Figure 7, Table 12 and Table 13. Weight Refer to Table 14. Block diagram Refer to Figure 8. Terminal connection Refer to Figure 9. Finish Valve body and bonnet; Blue (Munsell 10B5/10) or silver. Actuator ; Silver Table 1 Body/trim material combinations and operating temperature ranges (°C) Body material Trim material JIS FC200 SCPH2 SCPH21 SCPH61 SCPL1 SCS11 SCS13A SCS14A SCS16A SCS19A ASTM A126Gr.B A216WCB A217WC6 A217C5 A352LCB - A351CF8 A351CF8M A351CF3M A351CF3 JIS SUS304 0 ~ +200 -5 ~ +300 -45 ~ +300 -196 ~ +300 JIS SUS316 0 ~ +200 -5 ~ +300 -45 ~ +300 -196 ~ +300 -50 ~ +300 JIS SUS304L -45 ~ +300 -196 ~ +300 -196 ~ +300 JIS SUS316L -45 ~ +300 -196 ~ +300 -196 ~ +300 -196 ~ +300 -196 ~ +300 JIS SUS440C -5 ~ +425 -5 ~ +425 -5 ~ +425 JIS SUS329J1 -50 ~ +300 -196 ~ +300 JIS SUS304 Stellite -5 ~ +425 -5 ~ +550 -5 ~ +556 -45 ~ +350 -196 ~ +550 JIS SUS304 Stellite face -5 ~ +425 -5 ~ +550 -5 ~ +556 -45 ~ +350 -196 ~ +550 JIS SUS316 Stellite -5 ~ +425 -5 ~ +550 -5 ~ +556 -45 ~ +350 -196 ~ +550 -196 ~ +550 JIS SUS316Stellite face -5 ~ +425 -5 ~ +550 -5 ~ +556 -45 ~ +350 -196 ~ +550 -196 ~ +550 JIS SUS304L Stellite -45 ~ +350 -196 ~ +550 -196 ~ +450 JIS SUS316L Stellite -45 ~ +350 -196 ~ +450 -196 ~ +450 -196 ~ +450 -196 ~ +450 JIS SUS329J1 Stellite -50 ~ +550 -196 ~ +550 JIS SUS304 Soft seat 0 ~ +230 -50 ~ +230 -45 ~ +230 -80 ~ +230 JIS SUS316 Soft seat 0 ~ +230 -50 ~ +230 -45 ~ +230 -80 ~ +230 -80 ~ +230 JIS SUS316L Soft seat -45 ~ +230 -80 ~ +230 -80 ~ +230 -80 ~+ 230 -80 ~ +230 JIS SUS329J1 Soft seat -45 ~ +230 -80 ~ +230 Table 2 Cv value and travel Body material Trim material JIS SPH2 SCS13A SCS14A SCS16A SCS19A Titanium ASTM CW- 12MW Alloy 20 ASTM A216WCB A351CF8 A351CF8M A351CF3M A351CF3 JIS Titanium alloy -196 ~ +315 JIS Titanium -196 ~ +315 JIS ASTM CW- 12MW -196 ~ +450 JIS Alloy 20 -196 ~ +300 JIS Monel -5 ~ +300 -196 ~ +300 -196 ~ +300 -196 ~ +300 -196 ~ +300 -196 ~ +300 Note) “ ” shows standard combination of valve body and trim materials. 6 3