Azbil Corporation No. SS2-AGV200-0300 - 5 - 3-1-10 Structural drawing of trim and body/trim material combinations Following table shows typical body/trim material combinations. Please contact us about materials that are not listed in this table. Figure 10 Temperature and normal differential pressure ranges that require a Stellite Note)1) For valves for cavitation/flashing service, oil-proof service, or tight shutoff service, a stellite is recommended regardless of process fluid temperatures or differential pressures. 2) For valves for cavitation/flashing service for water or for valves for superheated water above 100 oC, SUS 440C is recommended. Figure 11 Temperature and maximum differential pressure ranges for soft seats Note)1) When there is a possibility of erosion by such fluids as saturated steam and heated water please use metal seats. 2) The material of washing treatment for oil-free of the wetted parts (inside the body) is PTFE with galss. a. With gude bushing b. Wighout guide bushing Figure 12 Structural drawing of trim Table 3 The valve body material is carbon steel (SCPH2/A216WCB). ..Valve plug ..Seat ring SUS316 SUS440C SUS316 Stellite SUS316 Stellite face SUS316 soft seat General Oil-free General General Oil-free General Oil-free ..Valve stem SUS316 ..Guide bushing SUS440C SUS316 Stellite face SUS440C SUS316 Stellite SUS316 Stellite SUS440C SUS316 Stellite face ..Seat gasket Without (Design temperature: -17 to +230oC) SUS316(PTFE coating) Without (Design temperature: -17 to +230oC) Without (Design temperature: -17 to +230oC) SUS316 (PTFE coating) Without SUS316 Monel (Design (PTFE coating) temperature: above +230oC) Monel (Design temperature: above +230oC) Monel (Design temperature: above +230oC) ..Bonnet gasket SUS316(PTFE coating) (Design temperature: -17 to +230oC) SUS316(PTFE coating) SUS316(PTFE coating) (Design temperature: -17 to +230oC) SUS316(PTFE coating) (Design temperature: -17 to +230oC) SUS316(PTFE coating) SUS316 (PTFE coating) SUS316 SUS316 (Design (PTFE coating) temperature: above +230oC) SUS316 (Design temperature: above +230oC) SUS316 (Design temperature: above +230oC) ..Valve plug ..Seat ring SUS316 SUS316L Stellite SUS316L soft seat General Oil-free General Oil-free General Oil-free ..Valve stem SUS316L ..Guide bushing SUS316L SUS316L Stellite face SUS316L Stellite SUS316L Stellite SUS316L SUS316L Stellite face ..Seat gasket Without (Design temperature: -17 to +230oC) SUS316(PTFE coating) Without (Design temperature: -17 to +230oC) SUS316(PTFE coating) Without SUS316(PTFE Monel coating) (Design temperature: above +230oC) Monel (Design temperature: above +230oC) ..Bonnet gasket SUS316(PTFE coating) (Design temperature: -17 to +230oC) SUS316(PTFE coating) SUS316(PTFE coating) (Design temperature: -17 to +230oC) SUS316(PTFE coating) SUS316(PTFE coating) SUS316(PTFE SUS316 coating) (Design temperature: above +230oC) SUS316 (Design temperature: above +230oC) -196 0 +100 +200 +300 +400 1470 {15} 981 {10} 490 {5} 0 Normal differential pressure kPa {kgf/cm2} Range that requires a stellite Fluid temperature ( C) -45 +100 +200 +230 2940 {30} 1470 {15} 2940 {30} 1470 {15} 490 {5} 0 Maximum differential pressure kPa {kgf/cm2} Fluid temperature ( C) PTFE with carbon fiber 3Valve stem 4Guide bushing 6Bonnet gasket 1Valve plug 2Seat ring 5Seat gasket 3Valve stem 6Bonnet gasket 1Valve plug 2Seat ring 5Seat gasket 6 1 |