No. SS2-GTX00R-0100 Azbil Corporation - 14 - Model GTX35R (for regular type / high-temperature service / oxygen service) (For option gM5h, 0.1mm thickness diaphragm) Material of wetted parts: 316 SST, 316L SST Flange size: Flush diaphragm 3 inches (80 mm) Extended diaphragm 4 inches (100 mm) Model GTX35R (for regular type / high-temperature / oxygen / chlorine service) Material of wetted parts: ASTM B575 (Hastelloy C-276 equivalent), Tantalum Flange size: Flush diaphragm 3 inches (80 mm) Model GTX40R (for regular type / high-temperature / oxygen / chlorine service) Material of wetted parts: ASTM B575 (Hastelloy C-276 equivalent), Tantalum Flange size: Flush diaphragm 3 inches (80 mm) *3: Within a range of URV > 0 and LRV > 0 *4: Reference accuracy at calibrated condition. Reference accuracy (*4) } 0.4% (For ƒÔ > 12.5 kPa (1250 mmH2O)) } (0.1 + 0.3 ~ )% (For ƒÔ < 12.5 kPa (1250 mmH2O)) Ambient Temperature effect (Shift from the set range) Change of 30 oC (Range from -5 to +55 oC) Combined shift } 2.84% (For ƒÔ > 25 kPa (2500 mmH2O)) } (1.52+ 1.32 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Static pressure effect (Shift from the set range) Change of 7 MPa (70 kgf/cm2) Zero shift } (0.06+ 1.44 ~ )% ƒÔ: kPa Combined shift } 2.00% (For ƒÔ > 25 kPa (2500 mmH2O)) } (0.06+ 1.94 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Reference accuracy (*4) } 0.4% (For ƒÔ > 12.5 kPa (1250 mmH2O)) } (0.25 + 0.15 ~ )% (For ƒÔ < 12.5 kPa (1250 mmH2O)) Ambient Temperature effect (Shift from the set range) Change of 30 oC (Range from -5 to +55 oC) Combined shift } 1.36% (For ƒÔ > 25 kPa (2500 mmH2O)) } (0.69 + 0.67 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Static pressure effect (Shift from the set range) Change of 7 MPa (70 kgf/cm2) Zero shift } 1.5% (For ƒÔ > 25 kPa (2500 mmH2O)) } (1.5 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Combined shift } 2.0% (For ƒÔ > 25 kPa (2500 mmH2O)) } (2.0 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Reference accuracy (*3)(*4) } 0.2% (For ƒÔ > 210 kPa (2.1 kgf/cm2)) } (0.05 + 0.15 ~ )% (For ƒÔ < 210 kPa (2.1 kgf/cm2)) Ambient Temperature effect (Shift from the set range) Change of 30oC (*3) (Range from -5 to +55 oC) Combined shift } 1.75% (For ƒÔ > 210 kPa (2.1 kgf/cm2)) } (1.00 + 0.75 ~ )% (For ƒÔ < 210 kPa (2.1 kgf/cm2)) Static pressure effect (Shift from the set range) Change of 7 MPa (70 kgf/cm2) Zero shift } (0.75 ~ )% ƒÔ: kPa Combined shift } (1.00 ~ )% ƒÔ: kPa 12.5 ƒÔ ---------- 25 ƒÔ ----- 25 ƒÔ ----- 25 ƒÔ ----- 12.5 ƒÔ ---------- 25 ƒÔ ----- 25 ƒÔ ----- 25 ƒÔ ----- 210 ƒÔ -------- 210 ƒÔ -------- 700 ƒÔ -------- 700 ƒÔ -------- |