No. SS2-GTX00R-0100 Azbil Corporation - 16 - Model GTX35R (for regular type / oxygen service), (capillary length 4m and 5m) Model GTX35R (for high-temperature service) Material of wetted parts: 316 SST, 316L SST Flange size: Flush diaphragm 1.5 inch (40 mm), 3/4 inches (20 mm), 1/2 inches (15 mm) Model GTX35R (for regular type / high-temperature service / oxygen service) Material of wetted parts: 316 SST, 316L SST Flange size: Extended diaphragm 2 inches (50 mm) Model GTX35R (for regular type / high-temperature / oxygen / chlorine service) Material of wetted parts: ASTM B575 (Hastelloy C-276 equivalent), Tantalum Flange size: Flush diaphragm 2 inches (50 mm), 1.5 inch (40 mm), 3/4 inches (20 mm), 1/2 inches (15 mm) Flange type code g1, 3h *3: Within a range of URV > 0 and LRV > 0 *4: Reference accuracy at calibrated condition. Reference accuracy (*4) } 0.3% (For ƒÔ > 12.5 kPa (1250 mmH2O)) } (0.15 + 0.15 ~ )% (For ƒÔ < 12.5 kPa (1250 mmH2O)) Ambient Temperature effect (Shift from the set range) Change of 30 oC (Range from -5 to +55 oC) Combined shift } 6.54% (For ƒÔ > 25 kPa (2500 mmH2O)) } (6.21 + 0.33 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Static pressure effect (Shift from the set range) Change of 7 MPa (70 kgf/cm2) Zero shift } 2.7% (For ƒÔ > 25 kPa (2500 mmH2O)) } (2.7 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Combined shift } 3.5% (For ƒÔ > 25 kPa (2500 mmH2O)) } (3.5 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Reference accuracy (*4) } 0.3% (For ƒÔ > 12.5 kPa (1250 mmH2O)) } (0.15 + 0.15~ )% (For ƒÔ < 12.5 kPa (1250 mmH2O)) Ambient Temperature effect (Shift from the set range) Change of 30 oC (Range from -5 to +55 oC) Combined shift } 6.54% (For ƒÔ > 25 kPa (2500 mmH2O)) } (6.21 + 0.33 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Static pressure effect (Shift from the set range) Change of 7 MPa (70 kgf/cm2) Zero shift } 2.7% (For ƒÔ > 25 kPa (2500 mmH2O)) } (2.7 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Combined shift } 3.5% (For ƒÔ > 25 kPa (2500 mmH2O)) } (3.5 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Reference accuracy (*4) } 0.4% (For ƒÔ > 12.5 kPa (1250 mmH2O)) } (0.25 + 0.15 ~ )% (For ƒÔ < 12.5 kPa (1250 mmH2O)) Ambient Temperature effect (Shift from the set range) Change of 30 oC (Range from -5 to +55 oC) Combined shift } 6.54% (For ƒÔ > 25 kPa (2500 mmH2O)) } (5.87 + 0.67 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Static pressure effect (Shift from the set range) Change of 7 MPa (70 kgf/cm2) Zero shift } 6.00% (For ƒÔ > 25 kPa (2500 mmH2O)) } (6.00 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Combined shift } 7.00% (For ƒÔ > 25 kPa (2500 mmH2O)) } (7.00 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) 12.5 ƒÔ ---------- 25 ƒÔ ----- 25 ƒÔ ----- 25 ƒÔ ----- 12.5 ƒÔ ---------- 25 ƒÔ ----- 25 ƒÔ ----- 25 ƒÔ ----- 12.5 ƒÔ ---------- 25 ƒÔ ----- 25 ƒÔ ----- 25 ƒÔ ----- |