yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz fi-01@@@108 / 226 10•bŒã‚ÉBOOK‚̃y[ƒW‚Ɉړ®‚µ‚Ü‚· |
|
Azbil Corporation No. SS2-GTX00R-0100 - 19 - Model GTX40R (for high temperature and vacuum / high temperature and high vacuum) Material of wetted parts: ASTM B575 (Hastelloy C-276 equivalent), Tantalum Flange size: Flush diaphragm 3 inches (80 mm) Model GTX35R (for high temperature and vacuum / high temperature and high vacuum) Material of wetted parts: 316 SST, 316L SST Flange size: Flush diaphragm 2 inches (50 mm), Extended diaphragm 3 inch (80 mm) Model GTX35R (for high temperature and vacuum / high temperature and high vacuum) Material of wetted parts: 316 SST, 316L SST Flange size: Flush diaphragm 1.5 inches (40 mm), Extended diaphragm 2 inches (50 mm) *3: Within a range of URV > 0 and LRV > 0. *4: Reference accuracy at calibrated condition. Reference accuracy (*3)(*4) } 0.2% (For ƒÔ > 210 kPa (2.1 kgf/cm2)) } (0.05 + 0.15 ~ )% (For ƒÔ < 210 kPa (2.1 kgf/cm2)) Ambient Temperature effect (Shift from the set range) Change of 30 oC (*3) (Range from -5 to +55 oC) Combined shift } 1.75% (For ƒÔ > 210 kPa (2.1 kgf/cm2)) } (1.00+ 0.75 ~ )% (For ƒÔ < 210 kPa (2.1 kgf/cm2)) Static pressure effect (Shift from the set range) Change of 7 MPa (70 kgf/cm2) Zero shift } (0.75 ~ )% ƒÔ: kPa Combined shift } (1.00 ~ )% ƒÔ: kPa Reference accuracy (*4) } 0.3% (For ƒÔ > 12.5 kPa (1250 mmH2O)) } (0.15+ 0.15 ~ )% (For ƒÔ < 12.5 kPa (1250 mmH2O)) Ambient Temperature effect (Shift from the set range) Change of 30 oC (Range from -5 to +55 oC) Combined shift } 4.0% (For ƒÔ > 25 kPa (2500 mmH2O)) } (3.33+ 0.67 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Static pressure effect (Shift from the set range) Change of 7 MPa (70 kgf/cm2) Zero shift } 6.0% (For ƒÔ > 25 kPa (2500 mmH2O)) } (6.0 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Combined shift } 7.0% (For ƒÔ > 25 kPa (2500 mmH2O)) } (7.0 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Reference accuracy (*4) } 0.3% (For ƒÔ > 12.5 kPa (1250mmH2O)) } (0.15+ 0.15 ~ )% (For ƒÔ < 12.5 kPa (1250 mmH2O)) Ambient Temperature effect (Shift from the set range) Change of 30 oC (Range from -5 to +55 oC) Combined shift } 6.54% (For ƒÔ > 25 kPa (2500 mmH2O)) } (5.87+ 0.67 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Static pressure effect (Shift from the set range) Change of 7 MPa (70 kgf/cm2) Zero shift } 6.0% (For ƒÔ > 25 kPa (2500 mmH2O)) } (6.0 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) Combined shift } 7.0% (For ƒÔ > 25 kPa (2500 mmH2O)) } (7.0 ~ )% (For ƒÔ < 25 kPa (2500 mmH2O)) 210 ƒÔ -------- 210 ƒÔ -------- 700 ƒÔ -------- 700 ƒÔ -------- 12.5 ƒÔ ---------- 25 ƒÔ ----- 25 ƒÔ ----- 25 ƒÔ ----- 12.5 ƒÔ ---------- 25 ƒÔ ----- 25 ƒÔ ----- 25 ƒÔ ----- 1 6 |