【DO!BOOK・ページリンク】 fi-01 112 / 226 10秒後にBOOKのページに移動します |
|
Azbil Corporation No. SS2-GTX00R-0100 - 23 - MODEL SELECTION Model GTX35R(Remote-sealed type for standard differential pressure) Model GTX40R(Remote-sealed type for high differential pressure) Flush 3 inches flange type for regular/ high temperature/ oxygen/ chlorine service) Model No.:GTX_ _R-Selection I(I II III IV V VI VII)-Selection II(I II III IV V VI)-Option *1 In case “Tantalum” is used for diaphragm material and in case of “For high-temperature service”, normal operating temperature of wetted parts is -10 to +180deg.C *2 In case code J is selected, code C “Tantalum” of Wetted parts material should be selected. *3 Not applicable for the combination with code A2 "With external Zero/Span adjustment", Q1 "Safety Transmitter", and Q2 "NAMUR NE43 Compliant Output signal limits" of Option. Basic Model No. Measuring span 2.5 to 100 kPa (250 to 10,160 mmH20) GTX35R Flush flange type 3 inches (80 mm) 35 to 700 kPa (0.35 to 7kgf/cm2) GTX40R Selection I I Output 4 to 20 mA (SFN Communication) A 4 to 20 mA (HART Communication) B Digital output (DE communication) *3 D II Fill fluid Regular type (Silicone oil) A For high temperature service (Silicone oil) B For oxygen service (Fluorine oil) H For chlorine service (Fluorine oil) *2 J III Wetted parts material 316 SST (Diaphragm:316L SST) A ASTM B575 (Equivalent to Hastelloy C-276) B Tantalum *1 C 316L SST D IV Flange rating ANSI150 A1 ANSI300 A2 ANSI600 A3 JIS10K J1 JIS20K J3 JIS30K J4 JIS63K J6 JPI150 P1 JPI300 P2 JPI600 P3 V Flange size 3 in./80 A F VI Flange type Flush type A VII Flange material/ bolt and nut material Flange Bolt and nut 304 SST 304 SST A 304 SST 630 SST C 304 SST Carbon steel D 316 SST 304 SST E 316 SST 630 SST G 316 SST Carbon steel H 316L SST 304 SST J 316L SST 630 SST L 316L SST Carbon steel M VIII Gasket face finish None Standard JISRa3.2(12.5S) A IX Capillary length 2 m 02 3 m 03 4 m 04 5 m 05 6 m 06 7 m 07 8 m 08 9 m 09 10 m 10 2 m (with Olefin Cover) A2 3 m (with Olefin Cover) A3 4 m (with Olefin Cover) A4 5 m (with Olefin Cover) A5 6 m (with Olefin Cover) A6 7 m (with Olefin Cover) A7 8 m (with Olefin Cover) A8 9 m (with Olefin Cover) A9 10 m (with Olefin Cover) A0 1 6 |