【DO!BOOK・ページリンク】 fi-01 113 / 226 10秒後にBOOKのページに移動します |
|
No. SS2-GTX00R-0100 Azbil Corporation - 24 - Model GTX35R (Remote-sealed type for standard differential pressure) Model GTX40R (Remote-sealed type for high differential pressure) Extended 4 inches flange type for regular/ high temperature/ oxygen/ chlorine service) Model No.:GTX_ _R-Selection I (I II III IV V VI VII) - Selection II (I II III IV V VI)-Option *1 In case Fill Fluid: For high-temperature service and Flange Rating: ANSI300 and Wetted Parts material: 316L SST, Extended length of flange 250/ 300 mm are not available. *2 Not applicable for the combination with code A2 "With external Zero/Span adjustment", Q1 "Safety Transmitter", and Q2 "NAMUR NE43 Compliant Output signal limits" of Option. *3 In case Fill Fluid: For high-temperature service, not applicable for the combination with wetted parts material "316L" and Flange Type "JIS30K". *4 In case Fill Fluid: Regular type or for oxygen service and Flange rating: JIS30K and wetted parts material: 316L SST, Extension length of Flange 150/200/250/300 mm are not available. Basic Model No. Measuring span 2.5 to 100 kPa (250 to 10,160 mmH20) GTX35R Extended flange type 4 inches (100 35 to 700 kPa (0.35 to 7 kgf/cm2) GTX40R mm) Selection I I Output 4 to 20 mA (SFN Communication) A 4 to 20 mA (HART Communication) B Digital output (DE communication) *2 D II Fill fluid Regular type (Silicone oil) A For high temperature service (Silicone oil) *1 B For oxygen service (Fluorine oil) H III Wetted parts material 316 SST (Diaphragm:316L SST) A 316L SST *3 *4 D IV Flange rating ANSI150 A1 ANSI300 *1 A2 JIS10K J1 JIS20K J3 JIS30K *3 *4 J4 JPI150 P1 JPI300 *1 P2 V Flange size 4 in./100 A G VI Flange type Extended Length 50 mm B Extended Length 100 mm C Extended Length 150 mm *4 D Extended Length 200 mm *4 E Extended Length 250 mm *1 *4 F Extended Length 300 mm *1 *4 G VII Flange material/ bolt and nut material Flange Bolt and nut 304 SST 304 SST A 304 SST 630 SST C 304 SST Carbon steel D 316 SST 304 SST E 316 SST 630 SST G 316 SST Carbon steel H 316L SST 304 SST J 316L SST 630 SST L 316L SST Carbon steel M VIII Gasket face finish None Standard JISRa3.2(12.5S) A IX Capillary length 2 m 02 3 m 03 4 m 04 5 m 05 6 m 06 7 m 07 8 m 08 9 m 09 10 m 10 2 m (with Olefin Cover) A2 3 m (with Olefin Cover) A3 4 m (with Olefin Cover) A4 5 m (with Olefin Cover) A5 6 m (with Olefin Cover) A6 7 m (with Olefin Cover) A7 8 m (with Olefin Cover) A8 9 m (with Olefin Cover) A9 10 m (with Olefin Cover) A0 |