【DO!BOOK・ページリンク】 fi-01 121 / 226 10秒後にBOOKのページに移動します |
|
No. SS2-GTX00R-0100 Azbil Corporation - 32 - Model GTX35R(Remote-sealed type for standard differential pressure) Model GTX40R(Remote-sealed type for high differential pressure) Extended 3 inches, 2 inches flange type for high temperature vacuum, high temperature high vacuum service Model No.:GTX_ _R-Selection I(I II III IV V VI VII)-Selection II(I II III IV V VI)-Option *1 In case of “ANSI/JPI600” is used for 3 in. Flange type and rating, not available for the extended diaphragm flange type. *2 In case Fill Fluid: For high-temperature service, and 2 in. Flange Rating: ANSI/JPI600 and Wetted Parts material: 316L SST, Extension length of Flange 200/250/300 mm are not available. *3 Not applicable for the combination with code A2 "With external Zero/Span adjustment", Q1 "Safety Transmitter", and Q2 "NAMUR NE43 Compliant Output signal limits" of Option. Basic Model No. Measuring span 2.5 to 100 kPa (250 to 10,160 mmH20) GTX35R Extended flange type 3 inches (80 mm), 35 to 700 kPa (0.35 to 7 kgf/cm2) GTX40R 2 inches(50 mm) Selection I I Output 4 to 20 mA (SFN Communication) A 4 to 20 mA (HART Communication) B Digital output (DE communication) *3 D II Fill fluid For high temperature vacuum service (Silicone oil) C For high temperature high vacuum service (Silicone oil) D III Wetted parts material 316 SST (Diaphragm:316L SST) A 316L SST D IV Flange rating ANSI150 A1 ANSI300 A2 ANSI600 *1 *2 A3 JIS10K J1 JIS20K J3 JIS30K J4 JPI150 P1 JPI300 P2 JPI600 *1 *2 P3 V Flange size 2 in./50 A E 3 in./80 A *1 F VI Flange type Extended Length 50 mm *1 B Extended Length 100 mm *1 C Extended Length 150 mm *1 D Extended Length 200 mm *1 E Extended Length 250 mm *1 F Extended Length 300 mm *1 G VII Flange material/ bolt and nut material Flange Bolt and nut 304 SST 304 SST A 304 SST 630 SST C 304 SST Carbon steel D 316 SST 304 SST E 316 SST 630 SST G 316 SST Carbon steel H 316L SST 304 SST J 316L SST 630 SST L 316L SST Carbon steel M VIII Gasket face finish None Standard JISRa3.2 (12.5S)) A IX Capillary length 2 m 02 3 m 03 4 m 04 5 m 05 |