Azbil Corporation No. SS2-GTX00U-0100 - 5 - Ambient temperature limits / Temperature ranges of wetted parts Note) *1: See the working pressures and temperatures of the wetted parts section in Figure 1, Figure 2 and Figure 4. *2: Ambient temperatures of the transmitter itself *3: Approximate values at the temperature of 25°C *4: Note that if the operating temperature falls below the lower limit of the normal operating range, the response of the transmitter becomes slower. *5: When the wetted parts material is tantalum, the upper limit is 180°C. *6: When the wetted parts material is tantalum, the upper limit is 200°C. *7: For G1-1/2" Bottom diaphragm Male connection, the Normal operating range is -40 to +110°C. *8: For G1-1/2" Bottom diaphragm Male connection, the Operative limit range is -50 to +115°C. *9: For G1-1/2" Bottom diaphragm Male connection, the Normal operating range is -10 to +75°C. *10: For G1-1/2" Bottom diaphragm Male connection, the Operative limit range is -40 to +85°C. Note) *1: See the working pressures and temperatures of the wetted parts section in Figure 2, Figure 3 and Figure 4. *2: Ambient temperatures of the transmitter itself. *3: Approximate values at the temperature of 25°C. *4: Note that if the operating temperature falls below the lower limit of the normal operating range, the response of the transmitter becomes slower. For Explosion proof models with digital indicators, which have to be used within the following ranges Normal operating condition -20 to 70°C Operative limit -30 to 80°C Temperature range (°C) *1 *4 Regular type High-temp. models High-temp. Vacuum models High-temp. High Vacuum models Oxygen and Chlorine models Wetted parts section Normal operating range -40 to 180 *7 -5 to 280 *5 -5 to 280 *5 10 to 300 *5 -10 to 120 *9 Operative limit range -50 to 185 *8 -10 to 310 *6 -10 to 310 *6 -10 to 310 *6 -40 to 125 *10 Ambient temperature *2 Flange size: Flush diaphragm type 3 inches (80 mm) Extended diaphragm type 4 inches (100 mm) Normal operating range -30 to 75 -5 to 55 -5 to 55 10 to 55 -10 to 75 Operative limit range -50 to 80 -10 to 60 -10 to 60 -10 to 60 -40 to 80 Ambient temperature Note 2 Flange size: Flush diaphragm type 2 inches (50 mm) / 1.5 inch (40 mm) Extended diaphragm type 3 inches (80 mm) / 2 inches (50 mm) Normal operating range -15 to 65 -5 to 45 -5 to 55 10 to 55 -10 to 75 Operative limit range -30 to 80 -10 to 55 -10 to 60 -10 to 60 -40 to 80 Specific gravity of fill liquid *3 0.935 1.07 1.07 1.09 1.87 Flange size: 3/4inches (20mm), 1/2 inches (15mm) Temperature range (°C) *1 *4 Regular type High-temp. models Oxygen and chlorine models Wetted parts section Normal operating range -40 to 180 -5 to 280 -10 to 120 Operative limit range -50 to 185 -10 to 310 -40 to 125 Ambient temperature *2 Normal operating range -15 to 65 -5 to 45 -10 to 75 Operative limit range -30 to 80 -10 to 55 -40 to 80 Specific gravity of fill liquid *3 0.935 1.07 1.87 1 7 |