【DO!BOOK・ページリンク】 fi-01 135 / 226 10秒後にBOOKのページに移動します |
|
No. SS2-GTX00U-0100 Azbil Corporation - 6 - Figure 5 Ambient temperature and temperature of wetted parts section (for general purpose models) [Flange size: Flush diaphragm 2 inches (50 mm) / 1.5 inch (40 mm) Extended diaphragm 3 inches (80 mm) / 2 inches (50 mm)] Note) When the fill liquid is for general purposes, make sure before using your transmitter that the conditions in both Figure 1, Figure 5 and Figure 6 are met. Figure 6 Ambient temperature and temperature of wetted parts section (for general purpose models) [Flange size: Flush diaphragm 3 inches (80 mm) Extended diaphragm 4 inches (100 mm)] Figure 7 Ambient temperature and temperature of wetted parts section (for high temperature and vacuum 2, 3m) [Flange size: Flush diaphragm 2 inches (50 mm) / 1.5 inch (40 mm)] Figure 8 Ambient temperature and temperature of wetted parts section (for high temperature and vacuum 4, 5 m) [Flange size: Flush diaphragm 2 inches (50 mm) / 1.5 inch (40 mm)] Figure 9 Ambient temperature and temperature of wetted parts section (for high temperature and high vacuum 2, 3 m) [Flange size: Flush diaphragm 2 inches (50 mm) / 1.5 inch (40 mm)] Figure 10 Ambient temperature and temperature of wetted parts section (for high temperature and high vacuum 4, 5 m) [Flange size: Flush diaphragm 2 inches (50 mm) / 1.5 inch (40 mm)] Ambient humidity limits 5 to 100% RH Stability against supply voltage change ± 0.005% FS/V Response time Approx. 400 ms (ref. value, with 5 m of ordinary capillaries, at room temp.) Damping time Selectable from 0 to 32 sec. in ten stages Lightning protection Applicable Standards; IEC 61000-4-5 Peak value of current surge(80/20μ sec.): 6000A Indicator The digital LCD indicator (optional) indicates engineering units and can be set freely between -99999 and 99999 (5 digits). For meter calibration, specify the following items when placing your order. . Meter calibration range . Meter calibration unit . Linear / Square-root for meter indication. Various kinds of data can be set using the communicator. Bolts and nuts materials (for fastening meter body cover) Carbon steel (SNB7), 304 SST, 630 SST Normal operating range Ambient temperature ( C) Temperature of wetted parts ( C) Operative limit range 100 80 75 72 68 50 -50 -40 100 110 150 180185 200 Ambient temperature ( C) Temperature of wetted parts ( C) 100 80 -50 -40 100 110 150 180185 200 Normal operating range Operative limit range 61 58 50 65 Ambient temperature ( C) Temperature of wetted parts ( C) 60 -10-5 165180 280 310 33 27 55 -5 -10 Normal operating range Operative limit range Ambient temperature ( C) Temperature of wetted parts ( C) 60 -10-5 100 125 280 310 30 27 55 -5 -10 Normal operating range Operative limit range Ambient temperature ( C) Temperature of wetted parts ( C) 60 -10 10 230240 280 310 47 43 55 10 -10 Normal operating range Operative limit range Ambient temperature ( C) Temperature of wetted parts ( C) 60 -10 10 160 190 280 310 41 39 55 10 -10 Normal operating range Operative limit range |