Azbil Corporation No. SS2-GTX00U-0100 - 7 - Paint Standard Corrosion-resistant paint (Baked acrylic paint) Corrosion-proof finish Corrosion-proof paint (Baked urethane paint), fungusproof finish OPTIONAL SPECIFICATIONS FEP protective film Use FEP protective films when corrosive fluids are used or to inhibition migration from metal diaphragms. Working temperature range 0 to 110°C Working pressure range Atmospheric pressure to flange rating (up to JIS10K, ANSI/JPI 150) (Not usable under negative pressure) Oil free finish The transmitter is shipped with oil-free wetted parts. (The vent drain plug is coated with a small amount of fluorine oil to prevent galling.) External zero/span adjustment function The transmitter can be easily zero/span adjusted in the field. Elbow This is an adaptor for changing the electrical conduit connection port from the horizontal to the vertical direction, if required by wiring conditions in the field. One or two elbows may be used as needed. Conformance to SI units We deliver transmitters set to any SI units as specified. Safety Transmitter Select this option to be used as a component of Safety Instrument System (SIS). AT9000 is complied with IEC61508, certified according to Safety Integrity Level2 (SIL-2) Alarm Output (contact output) Contact output is prepared as alarm output when alarm (Output Alarm/Sensor Temp. Alarm) condition is detected. It can be set to Normally Open. (When alarm is detected, Contact ON). Custom calibration Calibrate for the specified pressure range at the factory. PHYSICAL SPECIFICATIONS Materials Fill fluid Silicone oil for general purpose and high-temperature vacuum models Fluorine oil for oxygen and chlorine models For specific gravity, refer to “Ambient temperature limits / Temperature ranges of wetted parts” on page 5. Center body 316 SST Transmitter case Aluminum alloy, CF8M (Equivalent to 316 SST) Meter body cover 304 SST For Wetted parts 316 SST (316L SST for diaphragm only) ASTM B575 (Hastelloy C-276 equivalent), Tantalum, 316L SST Flange materials 304 SST, 316 SST, 316L SST Weight Approx. 13.5 kg (Including ANSI150 # - 3 inches flange and capillary 5 m long.) INSTALLATION Electrical connection 1/2NPT internal thread, M20 internal thread. Grounding Resistance 100 Ω max. Mounting Direct mounting on the process side Using 2-inch pipe mounting brackets: Mount the transmitter on a horizontal or vertical 2-inch pipe Bracket Carbon steel, 304 SST U-bolt and nuts 304 SST Process connection Measured pressure (liquid side) Flanges (both higher and lower pressure sides) Flush diaphragm JIS 10K, 20K, 30K and 63K: 40, 50, 80mm(RF) equivalents ANSI/JPI 150, 300 and 600: 1.5, 2, 3 inches (RF) equivalents ANSI/JPI 150 and 300: 1/2, 3/4 inches (RF) equivalents Extended diaphragm JIS 10K, 20K and 30K: 50, 80, 100mm(RF) equivalents ANSI/JPI 150, 300 and 600: 2, 3 inches (RF) equivalents ANSI/JPI 150 and 300: 4 inches (RF) equivalents Flange standard JIS; JIS B 2220 (2004) ANSI; ANSI B 16.5 (1988) JPI; JPI-7S-15-93 Screw connection G1. button diaphragm (G1. external thread) 1 7 |