【DO!BOOK・ページリンク】 fi-01 156 / 226 10秒後にBOOKのページに移動します |
|
Azbil Corporation No. SS2-GTX00U-0100 - 27 - Model GTX60U/GTX71U(Remote-sealed type for high gauge pressure) Model GTX82U(Remote-sealed type for highest gauge pressure) 2 inches wafer type for regular/ high temperature/ oxygen service Model No.:GTX_ _U-Selection I(I II III IV V VI VII VIII IX) - Selection II -Option *1 Not applicable for the combination with code A2 "With external Zero/Span adjustment", Q1 "Safety Transmitter" and Q2 "NAMUR NE43 Compliant Output Signal Limits" of Option. Basic Model No. Measuring span 35 to 3500kPa (0.35 to 35kgf/cm2) GTX60U 2 inches wafer type 0.7 to 10MPa (7 to 102kgf/cm2) GTX71U 0.7 to 42MPa (7 to 420kgf/cm2) GTX82U Selection I I Output 4 to 20mA (SFN Communication) A 4 to 20mA (HART Communication) B Digital output (DE communication) *1 D II Fill fluid Regular type (Silicone oil) A For oxygen service (Fluorine oil) H III Wetted parts material 316 SST (Diaphragm:316L SST) A 316L SST D IV Flange rating No flange XX V Flange size 2in. wafer type J VI Flange type Flush type A VII Flange material/ bolt and nut material Flange Bolt and nut No flange 630 SST 3 No flange Carbon steel 4 VIII Gasket face finish None Standard JISRa3.2(12.5S) A IX Capillary length 2m 02 3m 03 4m 04 5m 05 6m 06 7m 07 8m 08 9m 09 10m 10 2m (with Olefin Cover) A2 3m (with Olefin Cover) A3 4m (with Olefin Cover) A4 5m (with Olefin Cover) A5 6m (with Olefin Cover) A6 7m (with Olefin Cover) A7 8m (with Olefin Cover) A8 9m (with Olefin Cover) A9 10m (with Olefin Cover) A0 1 7 |