【DO!BOOK・ページリンク】 fi-01 157 / 226 10秒後にBOOKのページに移動します |
|
No. SS2-GTX00U-0100 Azbil Corporation - 28 - Model GTX60U/GTX71U(Remote-sealed type for high gauge pressure) 2 inches wafer type for high temperature vacuum, high temperature high vacuum service Model No.:GTX_ _U-Selection I(I II III IV V VI VII VIII IX)- Selection II -Option *1 Not applicable for the combination with code A2 "With external Zero/Span adjustment", Q1 "Safety Transmitter" and Q2 "NAMUR NE43 Compliant Output Signal Limits" of Option. Basic Model No. Measuring span 35 to 3500kPa (0.35 to 35kgf/cm2) GTX60U 2 inches wafer type 0.7 to 10MPa (7 to 102kgf/cm2) GTX71U Selection I I Output 4 to 20mA (SFN Communication) A 4 to 20mA (HART Communication) B Digital output (DE communication) *1 D II Fill fluid For high temperature vacuum service (Silicone oil) C For high temperature high vacuum service (Silicone oil) D III Wetted parts material 316L SST D IV Flange rating No flange XX V Flange size 2in. wafer type J VI Flange type Flush type A VII Flange material/ bolt and nut material Flange Bolt and nut No flange 630 SST 3 No flange Carbon steel 4 VIII Gasket face finish None Standard JISRa3.2(12.5S) A IX Capillary length 2m 02 3m 03 4m 04 5m 05 6m 06 7m 07 8m 08 9m 09 10m 10 |