【DO!BOOK・ページリンク】
fi-01   20 / 226

BOOKをみる

10秒後にBOOKのページに移動します


Azbil Corporation No. SS2-GTX00D-0100 - 17 - (Continued from previous page) *1 In case Manifold valve is used and in case code C, D is used, please select code A1 of Option. *2 Applicable for wetted parts of material (center body);316 SST (GTX31D, 41D, 71D) and ASTM B575 (GTX31D, 41D). *3 Applicable for wetted parts of material (center body); Tantalum (GTX31D, 41D, 71D), 316L SST (GTX31D, 41D, 71D) and ASTM B575 (GTX71D). *4 304 SST bolts and nuts material (-B) must be selected when PVC meterbody cover is selected.The max. working pressure is 1.5MPa. *5 When 304/316 SST bolt/nut is selected, max working pressure rating is 10MPa (100kgf/cm2). *6 In case code C, or D is selected, code A, or B of Process installation should be selected. *7 In case code J is selected, code C “Tantalum” of Material (centerbody) should be selected. *8 Please select A1 of option, when a wetted parts ASTM B575 of GTX71D is selected for assembling a manifold valve. *9 In case GTX71D, code C cannot be selected. *10 In case PVC is selected, code A, or D of Process connections should be selected. *11 In case PVC is selected, code A, or B of Process installation should be selected. *12 Not applicable for the combination with code F1, F6 of Explosion proof. *13 When a wetted parts ASTM B575 of GTX71D is selected, code A or B of process installation should be selected. *14 Not applicable for the combination with code A2 “With external Zero/Span adjustment”, Q1 “Safety Transmitter” and Q2 “NAMUR NE43 Compliant Output Signal Limits” of Option. *15 Not applicable for the combination with code D of Bolt/nut. *16 When a wetted parts ASTM B575 of GTX 71D is selected, code D of Bolt/nut cannot be selected. *17 In case this code is selected, code P8 of Option code should be selected. *18 In case code X, H, or D is selected, the material of transmitter case is aluminum alloy. *19 Not applicable for the combination with code E of Paint. Model No.:GTX_ _D-Selection I(I II III IV V VI VII)-Selection II(I II III IV V VI)-Option *4 No need to select when Fill Fluid code H, or J is selected. *5 Not applicable for the combination with code A2,or Q7 of Option. *6 Not applicable for the combination with code A, or B of Process installation. *7 Not applicable for the combination with code F1, F6 of Explosion proof. *8 Not applicable for any Explosion proof. Please select code XX “None” of Explosion proof. *9 Applicable for “ASTM B575”, code B of Material (center body). *10 Not applicable for the combination with code B “M20, Watertight” electrical connection. *11 Not applicable for the combination with code X “None” of Indicator. Please select “With indicator”. *12 Not applicable for the combination with “Tantalum” of diaphragm material. *13 Not applicable for the combination with code D “Digital output (DE communication)” of output. *14 Not applicable for the combination with code F2, F5, F6, N2, N5, E2, E5, A2 and A5 of Explosion proof. *15 In case code P8 is selected, code D of Bolt/nut should be selected. *16 In case code P8 is selected, code E of Paint should be selected. *17 In case code P8 is selected, code X or 2 of Mounting bracket shoult be selected. Option - No options XX Adapter flange for corrosion-resistant application (316L SST or Tantalum for the wetted parts of centerbody) A1 With external Zero/Span adjustment *11 *13 A2 One elbow (left) *6 *7 *10 G1 One elbow (right) *6 *7 *10 G2 2 elbows *6 *8 *10 G3 Long vent/drain plugs G4 Side vent/drain top *6 G6 Side vent/drain bottom *6 G7 Oil and water free finish K1 Oil free finish *4 K3 Au Plating Diaphragm *12 L1 316 SST (Parts in contact with atmosphere) *15 *16 *17 P8 Safety Transmitter *5 *13 Q1 NAMUR NE43 Compliant Output Signal Limits:3.8 to 20.5mA (Output 21.6mA/selected upper limit, 3.6mA/selected lower limit)*13 Q2 Alarm Output (contact output)*14 Q7 Custom calibration R1 Test report T1 Mill certificate T2 Traceability certificate T4 NACE certificate *9 T5 Non SI Unit W1 1 1