yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz fi-01@@@42 / 226 10•bŒã‚ÉBOOK‚̃y[ƒW‚Ɉړ®‚µ‚Ü‚· |
|
Azbil Corporation No. SS2-GTX00G-0100 - 3 - IECEx Intrinsic safety and Dust Certifications (Code E2) IECEx KEM 07.0058X Zone 0 Ex ia IIC T4 TPROCESS = 105 ‹C -30 ‹C < Tamb < +60 ‹C IP66 / 67 ELECTRICAL PARAMETERS: Ui = 30 V, Ii = 93 mA, Pi = 1 W, Ci = 5 nF, Li = 0.5 mH Ex iaD 20 IP66 / 67 T105 TPROCESS = 105 ‹C -30 ‹C < Tamb < +60 ‹C IECEx Type n and Dust Certifications (Code E5) IECEx KEM 07.0058X Ex nL IIC T4 TPROCESS = 105 ‹C -30 ‹C < Tamb < +60 ‹C IP66 / 67 ELECTRICAL PARAMETERS: Ui = 30 V, Ci = 5 nF, Li = 0.5 mH Ex tD A21 IP66 / 67 T85 TPROCESS = 85 ‹C -30 ‹C < Tamb < +75 ‹C Ex tD A21 IP66 / 67 T100 TPROCESS = 100 ‹C -30 ‹C < Tamb < +80 ‹C Ex tD A21 IP66 / 67 T110 TPROCESS = 110 ‹C -30 ‹C < Tamb < +80 ‹C KOSHA Flameproof (Code K1) Ex d II C T6 Tprocess = 85 ‹C -30 ‹C < Tamb < +75 ‹C Ex d II C T5 Tprocess = 100 ‹C -30 ‹C < Tamb < +80 ‹C Ex d II C T4 Tprocess = 110 ‹C -30 ‹C < Tamb < +80 ‹C EMC Conformity 89/336/EEC, 92/31/EEC, 93/68/EEC Electromagnetic Compatibility (EMC) Directive PED Conformity (97/23EC) The maximum pressures applicable under the Sound Engineering Practice (SEP) section of the Pressure Equipment Directive depend on the type of fluid measured, as shown in the table below. Note) Group 1 comprises fluids defines as: explosive, extremely flammable, highly flammable, flammable, very toxic, toxic and oxidizing. Group 2 comprises all other fluids not refer to group 1 Any AT9000 model having a maximum working pressure that is higher than the pressure corresponding to its group does not conform to SEP. Models GTX32D, 42D, 72D and 82G conform to PED according to Module A. Measuring span / Setting range / Working pressure range Note) 1) With PVC parts, the maximum working pressure is 1.5 MPa {15 kgf/cm2}. 2) With 304 SST bolts and nuts, the maximum working pressure is 10MPa {100 kgf/cm2}. 3) With 304 SST bolts and nuts, the maximum working pressure is 20 MPa {200 kgf/cm2}. Figure 1 Working pressure and temperature of wetted parts section (for general purpose models) Figure 2 Working pressure and temperature of wetted parts section (for oxygen and chlorine service) Measured fluid Group * Pressure Applicable models Gas 1 200 bar (20 MPa) All models except GTX32D, 42D, 72D, 82G 2 1,000 bar (100 MPa) All models Liquid 1 500 bar (50 MPa) All models 2 1,000 bar (100 MPa) All models Mo del Measuring Span Measuring range Overload Resistance value GTX 60G 17.5 to 3500 kPa {0.175 to 35 kgf/cm2} -100 to 3500 kPa {-1 to 35 kgf/cm2} (*1) 5250 kPa {52.5 kgf/cm2} GTX 71G 0.7 to 14 MPa {7 to 140 kgf/cm2} -0.1 to 14 MPa {-1 to 140 kgf/cm2} (*2) 21 MPa {210 kgf/cm2} GTX 82G 0.7 to 42 MPa {7 to 420 kgf/cm2} -0.1 to 42 MPa {-1 to 420 kgf/cm2} (*3) 63 MPa {630 kgf/cm2} 133.3 {1000} 101 80 53 27 13 8.0 5.3 1.3 2.0 {15} -50-40 40 50 60 70 80 90 100110 115 Normal operating range Operative limit Unusable range Operative limit Temperature of wetted parts ( C) Working Pressure P (kPa abs/{mmHg}) 133.3 101.3 53 -40 -10 0 40 75 80 Normal operating range Working pressure P kPa {mmHg} Temperature of wetted parts ( C) Unusable range {1000} {760} {400} 1 3 |