【DO!BOOK・ページリンク】 fi-01 44 / 226 10秒後にBOOKのページに移動します |
|
Azbil Corporation No. SS2-GTX00G-0100 - 5 - PHYSICAL SPECIFICATIONS Materials Fill fluid Silicone oil for general purpose models Fluorine oil for oxygen and chlorine models Center body 316 SST Transmitter case Aluminum alloy, CF8M (Equivalent to 316 SST) Meter body cover SCS14A (Equivalent to 316 SST) or 316 SST, PVC For Wetted parts Adapter flange (option) SCS14A (Equivalent to 316 SST), PVC Center body 316 SST (Diaphragm 316L SST) ASTM B575 (Equivalent to Hastelloy C-276), Tantalum, 316L SST Vents and plugs 316 SST, PVC Weight Approx. 3.6 kg (model GTX60G) INSTALLATION Electrical connection 1/2NPT internal thread, M20 internal thread. Grounding Resistance 100 Ω max. Mounting Can be installed on a 2-inch horizontal or vertical pipe (can be directly mounted on a process pipe) Process connection Rc1/2, 1/2NPT internal thread and Rc1/4, 1/4NPT internal thread. TRANSMITTER HANDLING NOTES To get the most from the performance this transmitter can offer, please use it properly noting the points mentioned below. Before using it, please read the Instruction Manual. Transmitter installation notes Wiring notes Handling precautions for HART specification devices . If you need to operate with a secondary host (HART communicator, etc.), set the communication interval of the primary host (DCS, device management system) to 8 seconds or more, or suspend communication from the primary host. If the primary host repeats HART communication within 8 seconds, the request from the secondary host may not be received (communication may not be possible). . If electrical noise in the environment prevents HARTcommunications with the host, take countermeasures such as separating the signal cables from the source of the noise, improving the grounding, changing to shielded signal cables, etc. Even if noise interferes with HART communications, the 4-20 mA analog signal will be unaffected and can be used for control. . If this product is being operated in multidrop mode, there is a limit to the number of devices that can be used. If you are using multidrop mode, please consult with us. WARNING . When installing the transmitter, ensure that gaskets do not protrude from connecting points into the process (such as adapter flange connection points and connecting pipes and flanges). Failure to do so may cause a leak of process fluid, resulting in harm from burns, etc. In addition, if the process fluid contains toxic substances, take safety measures such as wearing goggles and a mask to prevent contact with the skin and eyes and to prevent inhalation. WARNING . Use the transmitter within the operating ranges stated in the specifications (for explosionproofing, pressure rating, temperature, humidity, voltage, vibration, shock, mounting direction, atmosphere, etc.). Using the transmitter outside the operating conditions may cause device failure or fire, resulting in a harmful physical risk of burning or the like. . When performing wiring work in explosion-proof areas, follow the work method specified in the explosion-proof guidelines. CAUTION . After installation, do not use the transmitter as a foothold or put your weight on it. Doing so may cause damage. . Be careful not to hit the glass indicator with tools etc. This could break the glass and cause injury. . The transmitter is heavy. Wear safety shoes and take care when installing it. . Impact to transmitter can damage sensor module. WARNING . To avoid shocks, do not perform electrical wiring work with wet hands or with live wires. CAUTION . Do wiring work properly in conformance with the specifications. Wiring mistakes may result in malfunction or irreparable damage to the instrument. . Use a power supply that conforms to the specifications. Use of an improper power supply may result in malfunction or irreparable damage to the instrument. . Use a power supply with overcurrent protection for this instrument. 1 3 |