yDO!BOOKEƒy[ƒWƒŠƒ“ƒNz
fi-01@@@75 / 226

BOOK‚ð‚Ý‚é

10•bŒã‚ÉBOOK‚̃y[ƒW‚Ɉړ®‚µ‚Ü‚·


No. SS2-GTX00F-0100 Azbil Corporation - 4 - Supply voltage and load resistance 17.9 to 42V DC. Reverse polarity protection is standard. A load resistance of 250 ƒ¶ or more is necessary between loops. See Figure 3. Figure 3 .Supply voltage vs. load resistance characteristics Note) For communication with HART communicator, a load resistance of 250 ƒ¶ or more is necessary. Output Analog output (4 to 20 mA DC) with DE protocol Analog output (4 to 20 mA DC) with HART protocol Digital output (DE protocol) Output signal 3.6 to 21.6 mA 3.8 to 20.5 mA (NAMUR NE43 compliant) Failure Alarm Upper: 21.6 mA or more Lower: 3.6 mA or less Ambient temperature limits Normal operating range -30 to 75‹C for general purpose models -10 to 75‹C for oxygen and chlorine models -25 to 75‹C for models with digital indicators Operative limits -50 to 80‹C for general purpose models -40 to 80‹C for oxygen and chlorine models -30 to 80‹C for models with digital indicators Temperature ranges wetted parts Normal operating range -40 to 110‹C for general purpose models -20 to 75‹C for oxygen and chlorine models Operative limits -50 to 115‹C for general purpose models -40 to 80‹C for oxygen and chlorine models Ambient humidity limits 5 to 100% RH Stability against supply voltage change } 0.005% FS/V Response time Below 150 msec. (when damping time is set to 0 sec.) Damping time Selectable from 0 to 32 sec. in ten stages Lightning protection Applicable Standards; IEC 61000-4-5 Peak value of current surge(80/20ƒÊ sec.): 6000A Indicator The digital LCD indicator (optional) indicates engineering units and can be set freely between -99999 and 99999 (5 digits). For meter calibration, specify the following items when placing your order. . Meter calibration range . Meter calibration unit . Linear / Square-root for meter indication. Various kinds of data can be set using the communicator. Bolts and nuts materials (for fastening meter body cover) Carbon steel (SNB7), 304 SST, 630 SST Paint Standard Corrosion-resistant paint (Baked acrylic paint) Corrosion-proof finish Corrosion-proof paint (Baked urethane paint), fungusproof finish OPTIONAL SPECIFICATIONS FEP protective film Use FEP protective films when corrosive fluids are used or to avoid metal ions contact. Working temperature range 0 to 110‹C Working pressure range Atmospheric pressure to flange rating (up to JIS10K, ANSI / JPI 150) (Not usable under negative pressure) Oil free finish The transmitter is shipped with oil-free wetted parts. External zero/span adjustment function The transmitter can be easily zero/span adjusted in the field. Elbow This is an adaptor for changing the electrical conduit connection port from the horizontal to the vertical direction, if required by wiring conditions in the field. One or two elbows may be used as needed. Conformance to SI units We deliver transmitters set to any SI units as specified. 1345 1482 Supply voltage - 12.5 0.0219 245 0 17.9 42 45 Supply voltage (V DC) Operating Range = Operative limit 12.5