【DO!BOOK・ページリンク】
fi-01   96 / 226

BOOKをみる

10秒後にBOOKのページに移動します


Azbil Corporation No. SS2-GTX00R-0100 - 7 - Indicator The digital LCD indicator (optional) indicates engineering units and can be set freely between -99999 and 99999 (5 digits). For meter calibration, specify the following items when placing your order . Meter calibration range . Meter calibration unit . Linear / Square-root for meter indication. Various kinds of data can be set using the communicator. Bolts and nuts materials (for fastening meter body cover) Carbon steel (SNB7), 304 SST, 630 SST Paint Standard Corrosion-resistant paint (Baked acrylic paint) Corrosion-proof finish Corrosion-proof paint (Baked urethane paint), fungusproof finish OPTIONAL SPECIFICATIONS FEP protective film Use FEP protective films when corrosive fluids are used or to inhibition migration from metal diaphragms. Working temperature range 0 to 110°C Working pressure range Atmospheric pressure to flange rating (up to JIS10K, ANSI / JPI 150) (Not usable under negative pressure) Oil free finish The transmitter is shipped with oil-free wetted parts. External zero/span adjustment function The transmitter can be easily zero/span adjusted in the field. Elbow This is an adaptor for changing the electrical conduit connection port from the horizontal to the vertical direction, if required by wiring conditions in the field. One or two elbows may be used as needed. Conformance to SI units We deliver transmitters set to any SI units as specified. Safety Transmitter Select this option to be used as a component of Safety Instrumented System (SIS). AT9000 is complied with IEC61508, certified according to Safety Integrity Level2 (SIL-2) Alarm Output (contact output) Contact output is prepared as alarm output when alarm (Output Alarm/Sensor Temp. Alarm) condition is detected. It can be set to Normally Open. (When alarm is detected, Contact ON). Custom calibration Calibrate for the specified pressure range at the factory. PHYSICAL SPECIFICATIONS Materials Fill fluid Silicone oil for general purpose and high-temperature vacuum models Fluorine oil for oxygen and chlorine models For specific gravity, refer to Table 1 on page 5. Center body 316 SST Transmitter case Aluminum alloy, CF8M (Equivalent to 316 SST) Meter body cover SCS14A (Equivalent to 316 SST) For wetted parts SCS14A (316L SST for diaphragm only) ASTM B575 (Hastelloy C-276 equivalent), Tantalum, 316L SST Flange materials 304 SST, 316 SST, 316L SST Capillary section Capillary tube length 2, 3, 4, 5, 6, 7, 8, 9 and 10 m 2, 3, 4 and 5 m when flange diameter is flush diaphragm 2 inches (50 mm) / 1.5 inch (40 mm) 3/4 inches (20 mm), 1/2 inches (15mm) extended diaphragm 3 inches (80 mm) / 2 inches (50 mm) Capillary tube material 316 SST Armored tube material 304 SST Coating (optional) Olefin coating to improve corrosion resistance (Not applicable for high-temperature / Vacuum service type and High-temperature / High-vacuum service type.) Weight Approx. 20.0 kg (Including ANSI 150# - 3 inches flange and capillary 5 m long) INSTALLATION Electrical connection 1/2NPT internal thread, M20 internal thread. Grounding Resistance 100 Ω max. Mounting Direct mounting on the process side Using 2-inch pipe mounting brackets: Mount the transmitter on a horizontal or vertical 2-inch pipe. Bracket Carbon steel, 304 SST U-bolt and nuts 1 6