No. SS2-MGS200-0100 Azbil Corporation - 2 - FUNCTIONAL SPECIFICATIONS Type of protection JIS C 0920 watertight model NEMA ICS6-180 TYPE4X IEC PUBL 529 IP67 Size 15, 25, 40, 50, 80, 100, 125 mm (1/2, 1, 1., 2, 3, 4, 5 inches) Temperature range of process fluid Note) Steam sterilization Maximum steam temperature: 150°C(302°F) within one hour. Pressure range of process fluid -0.098 to +0.98 MPa (-14.2 to 142 psi) Ambient temperature limits -25 to +60°C (-13 to 140°F) (integral model) -30 to +80°C (-22 to 176°F) (remote model) Ambient humidity limits 5 to 100% RH Measurable electrical conductivity Combined with model MGG14C converter 3 μS/cm or more Vibration effect Integral style: 4.9m/s2(0.5G) max. Remote style converter: 4.9m/s2(0.5G) max. Remote style detector: 19.6m/s2(2G) max. Accuracy The standard accuracy is +/- 0.5% of rate. Also available is an optional high accuracy calibration rated at +/- 0.35% of rate (sizes of 40mm to 125mm(1. to 5 inches), combined with MGG14C). Optional specifications Test report Calibration certificate, withstand voltage test, insulation resistant, hydrostatic pressure test, physical inspection are included. Traceability certificate The following three documents are included. . Traceability System Chart . Traceability Certificate . Test Report Attaching the tag number to the terminal box Stamp the tag with the specified number and attach to the terminal box. The maximum number of characters of the tag number is 8. Attaching the tag number to the neck section Stamp the tag with the specified number and attach to the neck section of the detector with stainless wire. The maximum number of characters of the tag number is 16. Attaching the two spare gaskets When changing the gaskets, use these gaskets for ISO clamp or Tri-clamp. For additional specifications, please contact the Azbil Group representative. Diameter Temperature of the liquid to be measured Integral model Remote model 15 to 125 mm (1/2 to 5 inches) -40 to +120°C (-40 to +248°F) -40 to +160°C (-40 to +320°F) Measurement flow range Refer to the minimum / maximum set ranges shown in the table below. Diameter Minimum flow velocity range is 0 to 0.1 m/s (0 to 0.33 ft/s) Maximum flow velocity range is 0 to 10 m/s (0 to 32.8 ft/s) Conversion Minimum range Maximum range factor K mm inches m3/h GPM m3/h GPM 15 1/2 0 to 0.06362 0 to 0.2802 0 to 6.361 0 to 28.01 1.572 25 1 0 to 0.1768 0 to 0.7782 0 to 17.67 0 to 77.81 0.5659 40 1. 0 to 0.4524 0 to 1.993 0 to 45.23 0 to 199.2 0.2210 50 2 0 to 0.7069 0 to 3.113 0 to 70.68 0 to 311.2 0.1415 80 3 0 to 1.810 0 to 7.969 0 to 180.9 0 to 796.8 0.05526 100 4 0 to 2.828 0 to 12.46 0 to 282.7 0 to 1245 0.03537 125 5 0 to 4.418 0 to 19.46 0 to 441.7 0 to 1945 0.02264 |